微螺钉种植体支抗的口腔正畸效果分析 被引量:43

Efficacy of Microscrew Implant Anchorage in Orthodontics
下载PDF
导出
摘要 目的:探讨微螺钉种植体支抗在口腔正畸中的应用效果。方法:将80例成人双颌前突患者按支抗的不同分为治疗组与对照组,每组40例。两组患者均拔除4颗第一前磨牙,采用直丝弓矫治技术,其中治疗组采用微螺钉种植体支抗,对照组采用传统强支抗方法。用X线测量分析并比较两组患者的口腔正畸效果。结果:治疗组与对照组治疗前上中切牙唇倾角(U1-SN)、下中切牙唇倾角(L1-MP)和上下中切牙长轴的交角(U1-L1)测量值差异均无统计学意义(P>0.05);治疗后,治疗组U1-SN和L1-MP测量值均小于对照组,而U1-L1测量值则大于对照组,差异均有统计学意义(P<0.05)。所有患者完成治疗,且均未出现矫治器脱落、松动及局部感染等。结论:微螺钉种植体支抗的口腔正畸效果良好。 Objective:To investigate the clinical efficacy of microscrew implant anchorage in treatment of orthodontics. Methods: Eighty adult patients with double jaw protrusion were enrolled and divided into the treatment group and the control group according to the different anchorage methods, with 40 patients in each group. The control group used the traditional straight wire appliance for correction, and the treatment group used the microscrew implants for correction. X-ray analysis was applied to observe and compare orthodontic efficacys of two methods. Results: There were no statically differences in values of upper incisor labial inclination (U1-SN), lower incisor labial inclination(L1-MP), upper and lower incisor axis angle (U1-L1) values before treatment between the treatment group and the control group (P〈0. 05). However, after treatment, the values of U1-SN and L1-MP in the treatment group were lower than those in the control group, and U1-L1 value was higher than that in the control group (P〈0.05). All patients completed treatment, and no serious complications occurred. Conclusions: The efficacy of microscrew implant anchorage for the treatment of orthodontics is good.
出处 《中国临床医学》 2014年第2期221-222,共2页 Chinese Journal of Clinical Medicine
关键词 微螺钉种植体支抗 口腔正畸 直丝弓矫治器 Microscrew implant anchorage Orthodontics Straight wire appliances
  • 相关文献

参考文献5

二级参考文献9

  • 1Linkow, L. I.: Implanto-Orthodontics. Clin J Orthod 1970 4:685 - 705.
  • 2Roberts W E, Smith R K, Silberman Y et al. Osseous adaptation to continuous loading of rigid endosseous implants.Amer J Orthod 1984 86:95-111.
  • 3Van Roekel, N. B.: The use of Branemark System implants for orthodontic anchorage: Report of a case, Int. J. Oral maxillofac. Implants 4:341 - 344,1989.
  • 4Robens W. E.; Marshall, K. J. and Mozsary, P. G: Rigid endosseous implant utilized as anchorage to protract molars and close an atrOphic extraction site, Angle Orhtod. 60: 135 - 152,1990.
  • 5Higuchi, K.W. and Slack,J. M.: The use of titanium fixtures for intraoral anchorage to facilitate orthodontic tooth movement,Int. J. Oral Maxillofac. Implants 6: 338- 344,1991.
  • 6Block MS, Hoffman DR. A new device for absolute anchorage for orthodontics. Am J Orthod Dentofacial Orthop. 1995 Mar;107(3): 251- 8.
  • 7Park HS, Bae SM, Kyung HM, Sung JH. Micro-implant anchorage for treatment of skeletal Class Ⅰ bialveolar protrusion. J Clin Orthod. 2001 Jul; 35(7): 417 - 22.
  • 8王敏,韦选萍,赖毅伟.固定式横腭杆口外弓加强上颌磨牙支抗的比较研究[J].皖南医学院学报,2000,19(1):58-59. 被引量:5
  • 9伍军,吴建勇.安氏Ⅱ~1类错上颌尖牙远中移位后切牙及磨牙位置变化的研究[J].口腔正畸学,2001,8(2):69-71. 被引量:17

共引文献85

同被引文献225

引证文献43

二级引证文献168

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部