期刊文献+

75t/h CFB锅炉省煤器泄漏原因分析及改造方案研究 被引量:2

Analysis of Leak Reasons of 75t/h CFB Boiler Economizer and its Plans for Optimization and Improvement
下载PDF
导出
摘要 对锅炉省煤器的结构、分类以及设计原理进行了详细介绍,分析了省煤器爆管的主要原因:磨损、腐蚀、振动。针对延安炼油厂锅炉省煤器遇到的问题,对其进行了优化改进,通过分析及计算,改变省煤器的结构,由膜式改为光管错列式布置。改造后达到了预期的效果:提高了锅炉运行的安全可靠性。最后总结了省煤器改造后的效果,并且对于省煤器存在的主要问题及解决措施进行了分析总结。 This article introduces the structure, classification and the design principle of boiler economizer in detail, and points out the main reasons of economizer tube burst are abrasion, corrosion and vibration. And then considering the problems of boiler economizer in Yaffan Oil Refinery, the article changes the structure of the economizer from the membrane type into the staggered arrangement of light pipethrough analysis and calculation, so as to make the optimized improvement to the economizer. The optimized economizer can improve the safety and reliaility of boiler operation. Finally, the article summarizes the retrofitting results of the economizer and analyzes the main problems of the economizer and the solving measures.
作者 张峰
机构地区 延安炼油厂
出处 《绿色科技》 2014年第6期295-299,301,共6页 Journal of Green Science and Technology
关键词 省煤器 磨损 泄漏 飞灰冲蚀 优化改进 economizer abrasion leak fly ash erosion optimization and improvement
  • 相关文献

参考文献2

  • 1Rong--Hua Yeh. Optimum Finned Surfaces with Longitudinal Rectangular Fins[J]. Enhanced Heat Transfer, 2001 (8): 279-289.
  • 2楚洁品,宋泽普,陈福,韩松.膜片管束传热特性的研究[J].东北电力学院学报,1995,15(1):43-49. 被引量:3