摘要
简要介绍了噪声对人体的危害及液推加气子站产生噪声的原因,并以一座液推加气子站的噪声污染为例,结合现场环境,进行了治理,为加气子站液压橇外部设计新建了隔声降噪房,经治理前后现场实测数据的对比表明,噪声排放值已充分达标,符合国家标准,有效地改善了站场职工及周围居民的工作生活环境。可为同类加气站的噪声治理提供参考和借鉴。
The harms of noise to human body and the reasons causing noise of hydraulic piston type gas substation were briefly introduced.In order to control the noise of a hydraulic piston type gas substation,combining to the field environment,a new sound insulation room was built outside the hydraulic skid in the gas substation.According to the comparison of measured data before and after the treatment,the working and living environment of surrounding residents and the station field employees was effectively improved,providing the reference for the noise control of hydraulic piston type gas substation.
出处
《石油库与加油站》
2014年第3期8-10,共3页
Oil Depot And Gas Station
关键词
加气子站
噪音治理
探讨
gas filling substation
noise control
discussion