Experimental investigations of transient pressure variations in a high head model Francis turbine during start-up and shutdown 被引量:5

原文传递
导出
摘要 Penetration of the power generated using wind and solar energy to electrical grid network causing several incidents of the grid tripping, power outage, and frequency drooping. This has increased restart (star-stop) cycles of the hydroelectric turbines significantly since grid connected hydroelectric turbines are widely used to manage critical conditions of the grid. Each cycle induces significant stresses due to unsteady pressure loading on the runner blades. The presented work investigates the pressure loading to a high head ( He = 377 m, De = 1.78 m) Francis turbine during start-stop. The measurements were carried out on a scaled model turbine (HM = 12.5 m, DM = 0.349 m). Total four operating points were considered. At each operating point, three schemes of guide vanes opening and three schemes of guide vanes closing were investigated. The results show that total head variation is up to 9% during start-stop of the turbine. On the runner blade, the maximum pressure amplitudes are about 14 kPa and 16 kPa from the instantaneous mean value of 121 kPa during rapid start-up and shutdown, respectively, which are about 1.5 times larger than that of the slow start-up and shutdown. Moreover, the maximum pressure fluctuations are given at the blade trailing edge. Penetration of the power generated using wind and solar energy to electrical grid network causing several incidents of the grid tripping, power outage, and frequency drooping. This has increased restart (star-stop) cycles of the hydroelectric turbines significantly since grid connected hydroelectric turbines are widely used to manage critical conditions of the grid. Each cycle induces significant stresses due to unsteady pressure loading on the runner blades. The presented work investigates the pressure loading to a high head ( He = 377 m, De = 1.78 m) Francis turbine during start-stop. The measurements were carried out on a scaled model turbine (HM = 12.5 m, DM = 0.349 m). Total four operating points were considered. At each operating point, three schemes of guide vanes opening and three schemes of guide vanes closing were investigated. The results show that total head variation is up to 9% during start-stop of the turbine. On the runner blade, the maximum pressure amplitudes are about 14 kPa and 16 kPa from the instantaneous mean value of 121 kPa during rapid start-up and shutdown, respectively, which are about 1.5 times larger than that of the slow start-up and shutdown. Moreover, the maximum pressure fluctuations are given at the blade trailing edge.
出处 《Journal of Hydrodynamics》 SCIE EI CSCD 2014年第2期277-290,共14页 水动力学研究与进展B辑(英文版)
基金 the Swedish Waterpower Centre(SVC)for the financial support.SVC has been established by the Swedish Energy Agency,Elforsk and SvenskaKraftnat together with LuleUniversity of Technology,the Royal Institute of Technology,Chalmers University of Technology and Uppsala University(www.svc.nu)
  • 相关文献

参考文献3

二级参考文献4

共引文献18

同被引文献39

引证文献5

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部