期刊文献+

钢管混凝土轴压构件抗火承载力的计算 被引量:6

Load bearing Capacity of Fire resistance of Concrete Filled Steel Tubular Columns
下载PDF
导出
摘要 采用ECCS的计算模型和单元分析的计算模式 ,利用计算机程序 ,经过大量统计分析与计算 ,得到了钢管混凝土轴压构件抗火承载力的回归计算公式 ,并与国内外的结果对比 ,吻合较好 。 A large amount of statistic calculation on the squash load of centrally loaded concrete filled steel tubular columns exposed to fire has been carried out through using the computer program, and the regression formulas are established. From the comparisons of results respectively obtained by the formulas and experiments, it is concluded that the formulas are applicable with reasonable accuracy for fire resistant design of concrete filled steel tubular columns.
出处 《建筑结构》 CSCD 北大核心 2001年第1期60-62,59,共4页 Building Structure
关键词 钢管混凝土 抗火承载力 轴压构件 计算 concrete filled steel tubular columns centrally loaded fire resistant load bearing capacity
  • 相关文献

参考文献6

  • 1贺军利.钢管混凝土柱耐火性能的研究:博士学位论文[M].哈尔滨建筑大学,1998..
  • 2Wang Y C,Struct Eng Mech,1999年,7卷,2期,127页
  • 3李国强,钢结构抗火计算与设计,1999年
  • 4贺军利,博士学位论文,1998年
  • 5钟善桐,钢管混凝土结构,1994年
  • 6Lie T T,J Fire Prot Eng,1990年,2卷,4期,111页