针对广州新塘电厂2×330MW机组工程厂区布置的特殊性及局限性,文章详细分析论述了220kV配电装置采用屋内GIS型式非常规布置的设计过程及其特点,提出合适的布置方案,解决了220kV配电装置占地及出线问题,为类似工程提供借鉴。
The design and the characteristics of the non-conventional indoor GIS layout of 220kV distribution equip- ment were discussed and analyzed in the paper based on the particularity and limitation of plant layout of Guangzhou Xintang power plant, and a reasonable layout was proposed which solves the land occupation and outgoing line prob- lems of the 220kV distribution equipment and can be well referenced by similar projects.