摘要 目前大部分采用无GGH的石灰石-石膏湿法脱硫系统的火力发电厂,运行时易产生"石膏雨"问题.对石膏雨的形成原因和影响因素进行了分析,从提高除雾效率、提高净烟气温度、优化烟囱设计、优化运行调整4个方面提出了具体的防治措施. In most coal-fired power plants without GGH, limestone-gypsum wet flue gas desulfurization ( WFGD ) is prone to the phenomenon of gypsum rain in the emissions process. The factors affecting gypsum rain and reasons for the formation are studied. The measures in terms of improving the efficiency of mist eliminator, raising net flue gas temperature, optimizing the design of the chimney and optimizing operation of existing desulfurization facilities are put forward.
出处 《上海电力学院学报》 CAS 2014年第3期283-286,共4页 Journal of Shanghai University of Electric Power
基金 上海市科学技术委员会部分地方院校能力建设项目(13160501000) 上海发电环保工程技术研究中心项目(11dz2281700) 上海电力学院能源与机械工程学院"十二五"内涵建设项目("085"工程)
关键词 石膏雨 湿法脱硫 防治措施 火电厂 gypsum rain WFGD prevention and control measures coal-fired power plants