摘要
针对一个具体的SPF级别的动物房,分析了暖通空调系统设计、安装、调试中存在的问题,包括压差确定、洁净走廊布局、洁净度检测等,提出了相应的解决方案,指出了建设类似项目需要注意的问题。
Analyses the problems existing in design,construction,commissioning of HVAC system for a SPF animal house,including determination of pressure difference,distribution of clean corridors and detection of cleanliness. Proposes corresponding solutions, and points out the noticeable issues in construction of similar projects.
出处
《暖通空调》
北大核心
2014年第6期102-106,共5页
Heating Ventilating & Air Conditioning
关键词
动物房
空调系统
压力梯度
设计
施工调试
洁净度检测
SPF
SPF animal house
air conditioning system
pressure gradient
design
construction and commissioning
cleanliness detection