期刊文献+

两典型办公室室内颗粒物浓度监测与分析 被引量:5

Monitoring and Analysis of the Indoor Particulate Concentration of Two Typical Office Buildings
下载PDF
导出
摘要 对一普通办公楼及甲级办公楼办公室内、外颗粒物浓度进行监测。监测结果显示建筑室外颗粒物污染严重;普通办公楼室内颗粒物污染严重,甲级办公楼室内颗粒物浓度较低;甲级办公楼室内外颗粒物浓度I/O比值较普通办公楼小;两办公楼室内、外的PM2.5污染均较PM10污染频繁;室内人和物的剧烈活动、吸烟等活动会造成严重的室内颗粒物污染。 The indoor and outdoor PM concentration of both an ordinary and Grade-A office buildings was monitored. The results showed that outdoor PM concentration was relatively high and the indoor PM concentration in the ordinary office building was also high, however, the indoor PM concentrations in the Grade-A office building was relatively low; The I/O Ratio of indoor and outdoor PM concentration of Grade-A office building was lower than that of ordinary office buildings; indoor and outdoor PM2.5 pollution of the two office buildings were more serious than PM10 pollution; Intense indoor activities and smoking will result in severe indoor PM pollution.
出处 《建筑热能通风空调》 2014年第3期12-14,17,共4页 Building Energy & Environment
关键词 室内颗粒物浓度 I 0比 典型办公室 indoor particulate concentration, I/0 Ratio, typical office
  • 相关文献

参考文献6

  • 1http://www.epa.gov/air/particlepollution/health.html.[Z].
  • 2Paul L Lioy. The Total Human Environmental Exposure Study (THEES) to benzo(a)pyrene: comparison of the inhalation and food pathways [J]. Archives of Environment Health, 1988, 43 (4): 304-312.
  • 3Lance Wallace. A decade of studies of human exposure: what have we learned? [J]. Risk Analyis, 1993, 13(2): 135-139.
  • 4樊越胜,李安桂,司鹏飞.一般办公环境粉尘污染特征分析[J].暖通空调,2012,42(1):84-87. 被引量:2
  • 5段琼,张渝,李红格,房靖华.太原市某办公室PM_(10)与PM_(2.5)的实测与研究[J].能源研究与信息,2006,22(1):12-17. 被引量:12
  • 6世界卫生组织(WHO)空气质量准则[S].

二级参考文献26

  • 1赵厚银,邵龙义,王延斌,吕森林,刘永福.北京市冬季室内空气PM_(10)微观形貌及粒度分布[J].中国环境科学,2004,24(4):505-508. 被引量:22
  • 2Kreiss K. The epidemiology of building-relatedcomplaints and illness[J]. Occupy Med, 1989,4(4) : 575-592.
  • 3Bluyssen P M, de Oliveira F E, Groes L, et al. European indoor air quality audit project in 56 office buildings[J]. Indoor Air, 1996,6(4) :221- 238.
  • 4Alan H, Erikson W A. Predicting sick building syndrome at the individual and aggregate level[J]. Environment International, 1996,22(1) : 3-19.
  • 5Fisk W J, Rosenfeld A H. Potential nationwide improvements in productivity and health from better indoor environments [C]//Proceedings of ACEEE Summer Study'98, 1998 : 85- 97.
  • 6Katsouyanni K, Touloumi G, Spix C, et ak Short term effects of ambient sulphur dioxide and particulate matter on mortality in 12 European cities: results from time series data from the APHEA project[J]. British Medical Journal, 1997, 314(6): 1658-1663.
  • 7Samet J M, Dominici F, Zeger S L, et al. 2000a national morbidity, mortality, and air pollution study, part I: methods and methodological issues [R]. Research report 94, Part I. Health Effects Institute, Cambridge, MA, USA,2000.
  • 8Samet J M, Zeger S L, Schwatz J, et ak 2000b the national morbidity, mortality, and air pollution study. part II: morbidity, mortality, and air pollution in the United States[R]. Research report 94, Part Ⅱ. Health Effects Institute, Cambridge, MA, USA, 2000.
  • 9Monn C, Fuchs A, Hogger D, et ak Particulate matter less than 10 pm (PM10) and fine particles less than 2. 5 pm ( PM2. 5) : relationships between indoor, outdoor and personal concentrations[J]. The Science of the Total Environment, 1997, 208(1):15-21.
  • 10Biersteker K H, de Graaf, Nass C A G. Indoor airpollution in Rotterdam homes[J]. Int J Air Water Pollution, 1965, 6(9).- 343-350.

共引文献11

同被引文献63

引证文献5

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部