期刊文献+

阵发性房颤射频消融治疗对左房的影响 被引量:4

Influence to the size of left atrial after the first paroxysmal atrial fibrillation RFCA
下载PDF
导出
摘要 目的评价阵发性房颤首次射频消融治疗对左房大小的影响。方法50例药物治疗无效的症状性阵法性房颤患者,在EnsiteVelocity三维标测系统指导下行环肺静脉前庭线性消融,消融终点为肺静脉电隔离。结果术中肺静脉隔离率100%。术后32例成功维持窦律(维持窦律组),18例复发(复发组)。维持窦律组左房从38.3mm降至34.2mm,与射频消融前比较差异有统计学意义;复发组左房从38.6min升至39.1mm,但与射频消融前比较差异无统计学意义。结论阵发性房颤射频消融治疗能明确逆转左房重构。 Objective To study the influence to LA size after the first atrial fibrillation RFCA. Methods A total of 50 patients with PAF were treated with RFCA. The end point of RFCA was electrical isola- tion pulmonary vein potentials. Results All pulmonary vein was isolated. At follow-up, arrhythmias were eliminat- ed in 32 of 50(64%) patients after a first RFCA. The left atrial size were significantly smaller in those without re- currence. Conclusion RFCA can reverse LA remodle of patients with PAF.
出处 《中国心血管病研究》 CAS 2014年第6期526-527,共2页 Chinese Journal of Cardiovascular Research
关键词 阵发性房颤 射频消融 左房大小 Paroxysmal atrial fibrillation Radio frequence catheter ablation Left atrial size
  • 相关文献

参考文献5

  • 1Hobbs FD, Firzmaurice DA, Mant J, et al. A randomized con- trolled controlled trial and cost effectiveness study of systematic screening versue routine practice for the detection of atrial fibril- lation in people aged 65 and over. The SAFE Study. Health Technol Assess, 2005,9 : iii-iv, ix-x, 1-74.
  • 2Phang RS, Isserman SM, Karia D, et al. Echocardiographic evi- dence of left atrial abnormality in young patients with lone parox- ysmal atrial fibrillation. Am J Cardiol,2004,94:511-513.
  • 3Allessie M, Ausma J, Schotten U. Electrical contractile and structural remodeling during atrial fibrillation. Cardiovasc Res, 2002,54 : 230-246.
  • 4Berruezo A, Tamborero D, Mont L, et al. Pre-procedural pre- dictors of atrial fibrillation recurrence after circumferential pul- monary vein ablation. Euro Heart J, 2007,28:836.
  • 5Ollivier R, Donal E, Veillard D, et al. Early and late cardiac ven- tricular reverse remodeling after cather ablation for lone paroxys- mal atrial fibrillation. Ann Cardiol Angeiol(Paris), 2011,60:1-8.

同被引文献34

  • 1黄淑萍.阵发性房颤射频消融术后并发症的分析与护理[J].中国实用护理杂志(下旬版),2007,23(10):14-15. 被引量:2
  • 2Vieira ML, Cury AF, Naccarato G, et al. Analysis of left ven- tricular regional dyssynchrony: comparison between real time 3D echocardiography and tissue Doppler imaging. Echocardiography, 2009,26:675-683.
  • 3Soliman 01, van Dalen BM, Nemes A, et al. Quantification of left ventricular systolic dyssynchrony by real-time three -dimensional echocardiography.J Am Soc Echocardiogr,2009,22:232-239.
  • 4Suffoletto MS, Dohi K, Cannesson M, et al. Novel speckle-tracking radial strain from routine black -and -white echocardiographic images to quantify dyssynchrony and predict response to cardiac resynchronization therapy. Circulation, 2006 , 113 : 960-968.
  • 5Henein M, Zhao Y, Henein MY, et al. Disturbed left atrial mechanical function in paroxysmal atrial fibrillation: a speckle tracking study. IntJ Cardiol , 2012,155: 437-441.
  • 6Azar F, Perez de Isla L, Moreno M, et al. Three-dimensional echocardiographic assessment of left atrial size and function and the normal range of asynchrony in healthy individuals. Rev Esp Cardiol , 2009.62: 816-819.
  • 7Camm AJ. Kirchhof P. Lip GY. et al. Guidelines for the management of atrial fibrillation: the Task Force for the Management of Atrial Fibrillation of the European Society of Cardiology (ESC). Eur HeartJ. 2010.31 :2369-2429.
  • 8LeeJS. Shim CY. WiJ. et al. Left ventricular diastolic function is closely associated with mechanical function of the left atrium in patients with paroxysmal atrial fibrillation. CircJ, 2013,77 : 697-704.
  • 9Ojala T, Mathur S, Vatanen A, et al. Repeatability and agreement of real time three- dimensional echocardiography measurements of left ventricular mass and synchrony in young patients. Echocardiography, 2015,32: 522-527.
  • 10Driessen MM, Kort E, Cramer M1. et al. Assessment of LV ejection fraction using real-time 3D echocardiography in daily practice: direct comparison of the volumetric and speckle tracking methodologies to CMR. Neth Heart, 2014, 22: 383-390.

引证文献4

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部