摘要
为了利用堤坝温度监测得到的温度场信息反演出渗漏通道的流速,对线热源传热模型进行了优化,并利用室内试验进行了验证。结果表明:优化后的线热源模型在各试验工况下的误差均较小,最大误差为4.975%,能够模拟堤坝的实际传热状态。
To take advantafe of the temperature field information around the leakafe channel for monitorinf the flow rate in the dam,this paper proposed the line-heat-source conductive model by a reasonable optimization and desifned the laboratory tests to verify the theory. The results show that:the optimized line-heat-source model error in each test condition is smaller and the maximum error is 4. 975%. So this method can simulate the actual transfer state of dam.
出处
《人民黄河》
CAS
北大核心
2014年第6期30-32,共3页
Yellow River
基金
"十二五"国家科技支撑计划项目(2012BAB03B01)
关键词
传热模型
线热源模型
渗漏流速
堤坝
heat conductive model
line-heat-source model
leakafe flow rate
dam