摘要
讨论了硅化铂红外焦平面凝视成像系统光谱响应特性和测量方法.对其光谱响应特性进行了实验室定标,并分析比较了实验测量值和分离预期值.
The spectral response of a PtSi IR-FPA staring imaging system and its measurement are discussed.The spectral response calibration experiments for the PtSi IR-FPA system have been done in the laboratory.The anlysis and comparison between the experimental results and the mathematically predicted values are given.
出处
《红外与毫米波学报》
SCIE
EI
CAS
CSCD
北大核心
1994年第6期405-408,共4页
Journal of Infrared and Millimeter Waves
关键词
红外
凝视成像系统
光谱响应
定标
硅化铂
IR-staring imaging system,spectral response,spectrum calibration.