通过引进参量β1和β2,并测出维恩公式适用的波长λ1和λ2与某一特定波长λ0及相应的亮温T1s,T2s和T0s,将接近灰体的短波辐射源色温修正为真温.其修正的相对误差比直接由比辐射率测定的相对误差小倍.
By defining two parameters β1,β2,and by measuring wavelengths λ1,λ2 and a certain wavelength Ac as well as the corresponding brightness temperatures T1s,T2s and TOs,which are suited to the Wied's formula, an approximate method is presented for real temperature modified from the color temperature of a short-wave radiation source which is approximate to a gray body. The relative error of modification in the method is decreased by a factor of λ/2λ as compared with that based on the emissivity measurement.
出处
《红外与毫米波学报》
SCIE
EI
CAS
CSCD
北大核心
1994年第6期443-448,共6页
Journal of Infrared and Millimeter Waves
关键词
灰体
短波辐射源
色温
修正
真温
温度计