期刊文献+

评价迭代重建法与滤过反投影法在冠状动脉CTA检查中的价值 被引量:12

Evaluation of iterative AIDR and filtered back projection image algorithm on coronary computed tomography angiography
下载PDF
导出
摘要 目的:对行冠状动脉CTA检查的患者原始数据应用低剂量自适应迭代重建技术(AIDR)与滤过反投影法(FBP)两种方法的图像进行比较,旨在了解迭代重建算法的图像质量及其临床应用价值。方法:26例临床疑似稳定性心绞痛患者采用320排CT行冠状动脉CTA检查。利用AIDR重建的常规X线剂量方案扫描,对采集得到的原始数据分别用AIDR和FBP两种方法进行图像重建。测量升主动脉开口、右冠状动脉近段、左冠状动脉主干、右冠状动脉中段、左前降支近段及左回旋支近段的CT值、背景SD并计算分析SNR、CNR值。比较两者的图像质量。结果:26例患者都在一次心动周期完成冠状动脉检查。在血管各节段测得的平均CT值差异无统计学意义(P>0.05),背景SD值的差异有统计学意义(P<0.001),计算得到的SNR、CNR差异有统计学意义(P<0.001)。两组图像质量的主观评分差异有统计学意义,AIDR(3.73±0.49)、FBP(3.59±0.61)(P<0.01)。结论:应用AIDR重建法的图像质量优于FBP重建法,迭代重建技术可明显降低图像噪声,改善影像质量并具有降低辐射剂量的作用。 Objective:To compare the image qualities of coronary computed tomography angiography (CCTA)using adaptive iterative dose reduction (AIDR)and filtered back projection (FBP)algorithm and to evaluate the clinical value of AIDR.Methods:Twenty-six patients with suspected stable angina underwent regular radiation dose scanning protocol on 320 MDCT scanner.The collected raw data were then reconstructed with AIDR and FBP respectively.CT value and background SD value were measured at the aorta root,proximal and middle right coronary artery,left main coronary artery,proximal left anterior artery,as well as proximal left circumflex artery.SNR and CNR were also calculated.Two observers compared the quality of the images with subjective grading.Results:Twenty-six patients completed CCTA within one heart beat.The average CT attenuation measured at segments of coronary arteries was not statistically different (P〉0.05).Back-ground SD value,SNR and CNR calculated were statistically different (P〈0.001).The subjective grading of image qualities between two groups were 3.73±0.49 for AIDR and 3.59±0.61for FBP,respectively,and was statistically different (P〈0.01).Conclusion:The quality of images reconstructed with AIDR was better than that of FBP.AIDR can reduce the imaging noise significantly,improve the image quality and help reducing radiation dose potentially.
出处 《放射学实践》 2014年第6期663-667,共5页 Radiologic Practice
关键词 冠状动脉疾病 血管造影术 体层摄影术 X线计算机 图像处理 计算机辅助 Coronary artery disease Angiography Image processing,computer-assisted Tomography,X-ray com-puted
  • 相关文献

参考文献2

二级参考文献8

  • 1Fishman EK, Ney DR, Heath DG, et al. Volume rendering versus maximum intensity projection in CT angiography: what works best, when, and why. RadioGraphics, 2006, 26:905 - 922.
  • 2Suzuki S, Furui S, Kaminaga T, et al. Measurement of vascular diameter in vitro by automated software for CT angiography: effects of inner diameter, density of contrast medium, and convolution kernel. AJR, 2004, 182: 1313- 1317.
  • 3Addis KA, Hopper KD, lyriboz TA, et al. CT angiography: in vitro comparison of five reconstruction methods. A JR, 2001,177: 1171- 1176.
  • 4Das M, Mahnken AH, Muhlenbruch G, et al. Individually adapted examination protocols for reduction of radiation exposure for 16 - MDCT chest examinations. A JR, 2005, 184: 1437- 1443.
  • 5Hur G, Hong SW, Kim SY, et al. Uniform image quality achieved by tube current modulation using SD of attenuation in coronary CT angiography. AJR, 2007, 189: 188- 196.
  • 6Rizzo S, Kalra M, Schmidt B, et al. Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis. AJR, 2006, 186:673 - 679.
  • 7Frush DP, Slack CC, Hollingsworth CL, et al. Computer- simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. AJR, 2002,179: 1107- 1113.
  • 8高建华,王贵生,李剑颖,孙宪昶,韩文娟,赵雯,戴汝平.64层螺旋CT冠状动脉成像低剂量技术的应用价值[J].临床放射学杂志,2008,27(3):388-391. 被引量:32

共引文献86

同被引文献111

  • 1Xu J, Mahesh M, Tsui BM. Is iterative reconstruction readyfor MDCT?[J]. J Am Coll Radiol, 2009, 6(4): 274-276.
  • 2Hara AK, Paden RG, Silva AC, et al. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study[J]. Am J Roentgenol, 2009, 193(3): 764-771.
  • 3Gupta AK, Nelson RC, Johnson GA, et al. Optimization of eight-element multi-detector row helical CT technology for evaluation of the abdomen[J]. Radiology, 2003, 227(3): 739-745.
  • 4Pontana F, Duhamel A, Pagniez J, et al. Chest computed tomography using iterative reconstruction vs filtered back projection (part 2): image quality of low-dose CT examinations in 80 patients[J]. Eur Radiol, 2011, 21(3): 636-643.
  • 5Gervaise A, Osemont B, Lecocq S, et al. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT[J]. Eur Radiol, 2012, 22(2): 295-301.
  • 6Tatsugami F, Matsuki M, Nakai G, et a1. The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography[J]. Br J Radiol, 2012, 85 (1016): e378-e382.
  • 7Silva AC, Lawder HJ, Hara A, et al. Innovations in CT dosereduction strategy: application of the adaptive statistical iterative reconstruction algorithm[J]. Am J Roentgenol, 2010, 194(1): 191-199.
  • 8Austen W G,Edwards J E,Frye R L,et al. A reporting system on patients evaluated for coronary artery disease, report of the Ad Hoe Committee for Grading of Coronary Artery Diease, Council on Cardiovascular Surgery, American Heart Association[J]. Cir- culation,1975,51(4 Suppl):5-40.
  • 9Husmann L, Alkadhi H, Boehm T, et al. Influence of cardiac he- modynamic parameters on coronary artery opaeification with 64- slice computed tamography[J]. Eur Radiol, 2006,16 ( 5 ) : 1111 - 1116.
  • 10Pflederer T, Rudofsky L, Ropers D, et al. Image quality in a low radiation exposure protocol for retrospectively ECG-gated coro- nary CT angiography[J]. AJR, 2009,192(4) : 1045- 1050.

引证文献12

二级引证文献76

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部