摘要
介绍了唐山唐钢气体有限公司20000 m3/h空分装置增压通道带水事故经过及快速处理过程,在主冷不排液的情况下采用局部加热的方式将增压通道内水分吹除干净,恢复了设备正常运行。
A water entrainment accident in the pressurizing air channel of the 20000 m3/h air separation plant of Tangshan Steel and its immediate treatment are introduced. With failure of the main condenser to remove water the method of local heating was adopted to blow off the moisture in the pressurizing air channel, which resumed normal operation of the equipment.
出处
《冶金动力》
2014年第6期35-37,共3页
Metallurgical Power
关键词
增压通道
带水事故
膨胀机
加热吹除
快速处理
预防措施
pressurizing channel
water entrainment accident
expanding machine
blow off by heating
immediate treatment