期刊文献+

密封箱式炉的检测与分析 被引量:2

Performance Survey of Seal Box Furnace
下载PDF
导出
摘要 借助专用设备和仪器,对江苏丰东热技术股份有限公司生产、工作区尺寸为1200 mm×600 mm×600 mm的密封箱式炉的性能,包括空载升温时间、空载能耗、温度均匀性及表面温升等,进行了检测。结果表明,该密封箱式炉的空炉升温时间为4.133 3 h,空炉能耗为700.8 kWh,炉温均匀度为+2.7℃/-1.8℃,炉壁左侧、右侧及后侧的表面温升分别为44.97℃、44.67℃和37.23℃,符合标准要求。 A certain seal box furnace with a working zone measuring 1200 mm long by 600 mm wide by 600 mm high, made in Jiangsu Fengdong Thermal Technology Co.,Ltd., was subjected to performance survey by means of some special equipments and instruments, the survey items involving no-load heating-up time, no-load energy consumption, temperature uniformity and surface temperature rise. The results show that the no-load heating-up time is 4. 133 3 h, the no-load energy consumption is 700. 8 kWh, the temperature variation is + 2.7 ℃/ - 1.8 ℃, the surface temperature rise at left, right and back furnace walls are 44.97 ℃ 44.67 ℃ and 37.23 ℃ respectively
出处 《热处理》 CAS 2014年第3期67-69,共3页 Heat Treatment
关键词 密封箱式炉 检测 炉温均匀性 conforming with the related standards : seal box furnace survey furnace temperature uniformity
  • 相关文献

参考文献7

  • 1GB/T10067.4-2005,电热装置基本技术条件第4部分:间接电阻炉[S].
  • 2GB/T9452--2003,热处理炉有效加热区测定方法[S].
  • 3GB/T10066.4-2004,电热设备的试验方法第4部分:间接电阻炉[S].
  • 4GB/T15318--2010,热处理电炉节能监测[S].
  • 5HB5425-1989,航空制件热处理炉有效加热区测定方法[S]
  • 6左霞.热处理炉炉温均温性测试方法及结果评定[J].计测技术,2010,30(3):62-63. 被引量:7
  • 7JB/T8195.1--1999,间接电阻炉RX系列箱式电阻炉[S].

二级参考文献2

  • 1JJF1101-2003环境试验设备温度校准规范[S].
  • 2GB/T 9452-2003,热处理炉有效加热区测定方法[S].

共引文献7

同被引文献6

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部