摘要
目的为了解我省现有民营医疗机构消毒供应室压力蒸汽灭菌器管理现状,为今后有针对性的加强民营医疗机构管理提供依据。方法压力蒸汽灭菌器的灭菌效果采用3M综合挑战测试包进行验证,温度采用温度测定仪进行。结果民营医院的常规监测不到位,温度测定结果与生物监测结果通过率存在显著性差异。结论加强人员知识更新,强化医院感染管理意识,加强压力蒸汽灭菌器的监管力度。
Objective to study the management status of the pressure steam sterilizer in the existing private medical institutions, in order to provide the basis for strengthening the management of private medical institutions. Methods using 3M comprehensive challenge test package to test the pressure steam sterilizer sterilization effect, a temperature detector for temperature. Results civilian battalion hospital routine surveillance does not reach the designated position, temperature measurement results pass rate exists significant difference with the biological monitoring results. Conclusions personnel knowledge update and the.regulation of the pressure steam sterilizer should be strengthened, the consciousness of the hospital infection management should be enhanced.
出处
《中国卫生标准管理》
2014年第8期48-50,共3页
China Health Standard Management
基金
黑龙江省卫生厅2013年立项课题(编号:2013400)
关键词
消毒
压力蒸汽灭菌
调查
Disinfection
Pressure steam sterilizer
Survey