摘要 某核电厂凝结水精处理系统废水中和池的废水排放泵叶轮在使用仅4个月的情况下发生了严重的腐蚀问题。本文通过宏微观分析、化学成分分析、金相分析等手段对失效叶轮腐蚀原因进行分析,结果表面:叶轮碳含量偏高,在晶界形成碳化物,从而发生了晶间腐蚀。 The Impeller of waste water pump were corroded on daily inspection in a domestic nuclear power plant.The investigation for the failure including chemical composition analysis,microstructure observation,and so on. The results indicated that the carbon element of the impeller was more than the standard composition and cause intercrystalline corrosion.
出处 《全面腐蚀控制》 2014年第6期79-82,共4页 Total Corrosion Control
关键词 核电厂 叶轮 晶间腐蚀 nuclear power plant impeller intercrystalline corrosion
  • 相关文献

参考文献7

  • 1古特曼 E M,金石译.金属力学化学与腐蚀防护[M].北京:科学出版社,1989:34.
  • 2Bampton C C, Jones I P, Loretto M H. Stacking fault energy measurements in some austenitic stainless steels[J].Acta Metall, 1978, 26:38.
  • 3Berns H, Ktlhl A. Reduction in wear of sewage pump through solution nitriding[J]. Wear, 2004, 256:16.
  • 4Levy A V, Yau P. Erosion of steels in liquid slurries[J]. Wear, 1984, 98:163.
  • 5郑玉贵,姚治铭,张玉生,魏翔云,柯伟.冲刷与腐蚀的交互作用与耐冲刷腐蚀合金设计[J].金属学报,2000,36(1):51-54. 被引量:33
  • 6Fu W T, Zheng Y Z, Jing T F, Yao M. Structural changes after cavitation erosion for a Cr-Mn-N stainless steel[J]. Wear, 1997, 205:28.
  • 7Zheng Y G, Yao Z M, Wei X Y, Ke W. The synergistic effect between erosion and corrosion in acidic slurry medium[J]. Wear, 1995, 186-187:555.