摘要
利用恒流恒阻连续放电的方法寻找碱锰电池放电条件与放电时间或容量的关系 ,达到预测电池连续放电容量或放电时间的目的 .研究结果表明 ,在一定的生产工艺条件下 ,LR0 3型碱锰电池在恒流恒阻连续放电时 ,放电容量 C与恒流连放电流或恒阻连放平均电流 I间满足C=K/In-1方程 .在一定的放电电阻范围内 ,恒阻连放的放电电阻 R与有效放电时间 t符合t=m· R-
relationship between the discharge conditions of alkaline Zn/MnO 2 batteries and the discharge time or the capacity is determined by means of continuous discharge with fixed resistance and at constant current, in order to predict the capacity and discharge time when the batteries discharge continuously. It can be shown that the equation, C=K/I n-1 , is fitted between the capacity and discharge current or average discharge current when alkaline Zn/MnO 2 batteries for LR03 type discharge continuously with fixed resistance and at constant current under the limited production technology. When the batteries discharge continuously with fixed resistances, the equation, t=mR-B , is fitted between effective discharge time and discharge resistance within the limits permitted.
出处
《郑州轻工业学院学报》
2001年第1期47-50,共4页
Journal of Zhengzhou Institute of Light Industry(Natural Science)