期刊文献+

Connecting parameters optimization on unsymmetrical twin-tower structure linked by sky-bridge 被引量:1

Connecting parameters optimization on unsymmetrical twin-tower structure linked by sky-bridge
下载PDF
导出
摘要 Based on a simplified 3-DOF model of twin-tower structure linked by a sky-bridge,the frequency response functions,the displacement power spectral density(PSD)functions,and the time-averaged total vibration energy were derived,by assuming the white noise as the earthquake excitation.The effects of connecting parameters,such as linking stiffness ratio and linking damping ratio,on the structural vibration responses were then studied,and the optimal connecting parameters were obtained to minimize the vibration energy of either the independent monomer tower or the integral structure.The influences of sky-bridge elevation position on the optimal connecting parameters were also discussed.Finally,the distribution characteristics of the top displacement PSD and the structural responses,excited by El Centro,Taft and artificial waves,were compared in both frequency and time domain.It is found that the connecting parameters at either end of connection interactively affect the responses of the towers.The optimal connecting parameters can greatly improve the damping connections on their seismic reduction effectiveness,but are unable to reduce the seismic responses of the towers to the best extent simultaneously.It is also indicated that the optimal connecting parameters derived from the simplified 3-DOF model are applicable for two multi-story structures linked by a sky-bridge with dampers.The seismic reduction effectiveness obtained varies from 0.3 to 1.0 with different sky-bridge mass ratio.The displacement responses of the example structures are reduced by approximately 22% with sky-bridge connections. Based on a simplified 3-DOF model of twin-tower structure linked by a sky-bridge, the frequency response functions, the displacement power spectral density (PSD) functions, and the time-averaged total vibration energy were derived, by assuming the white noise as the earthquake excitation. The effects of connecting parameters, such as linking stiffness ratio and linking damping ratio, on the structural vibration responses were then studied, and the optimal connecting parameters were obtained to minimize the vibration energy of either the independent monomer tower or the integral structure. The influences of sky-bridge elevation position on the optimal connecting parameters were also discussed. Finally, the distribution characteristics of the top displacement PSD and the structural responses, excited by El Centro, Taft and artificial waves, were compared in both frequency and time domain. It is found that the connecting parameters at either end of connection interactively affect the responses of the towers. The optimal connecting parameters can greatly improve the damping connections on their seismic reduction effectiveness, but are unable to reduce the seismic responses of the towers to the best extent simultaneously. It is also indicated that the optimal connecting parameters derived from the simplified 3-DOF model are applicable for two multi-story structures linked by a sky-bridge with dampers. The seismic reduction effectiveness obtained varies from 0.3 to 1.0 with different sky-bridge mass ratio. The displacement responses of the example structures are reduced by approximately 22% with sky-bridge connections.
出处 《Journal of Central South University》 SCIE EI CAS 2014年第6期2460-2468,共9页 中南大学学报(英文版)
基金 Project(51178203)supported by the National Natural Science Foundation of China
关键词 结构连接 双塔结构 参数优化 天桥 不对称 频率响应函数 连接参数 结构振动响应 twin-tower connected structure sky-bridge connecting parameter optimization seismic response
  • 相关文献

参考文献2

二级参考文献23

  • 1Abdullah, M.M., Hanif, J.H., Richardson, A., Sobanjo, J., 2001. Use of a shared tuned mass damper (STMD) to reduce vibration and pounding in adjacent structures. Earthquake Engineering and Structural Dynamics, 30(8): 1185-1201. [doi:lO.1002/eqe.58].
  • 2Basili, M., De Angelis, M., 2007. Optimal passive control of adjacent structures interconnected with nonlinear hyster- etic devices. Journal of Sound and Vibration, 301(1-2): 106-125. [doi: a 0.1016/j.jsv.2006.09.027].
  • 3Bharti, S.D., Dumne, S.M., Shrimali, M.K., 2010. Seismic response analysis of adjacent buildings connected with MR dampers. Engineering Structures, 32(8):2122-2133. [doi:l 0.1016/j.engstruct.2010.03.015].
  • 4Bhaskararao, A.V., Jangid, R.S., 2006a. Seismic response of adjacent buildings connected with friction dampers. Bul- letin of Earthquake Engineering, 4(1):43-64. [doi:10. 1007Is10518-005-5410-1 ].
  • 5Bhaskararao, A.V., Jangid, R.S., 2006b. Seismic analysis of structures connected with friction dampers. Engineering Structures, 28(5):690-703. Idol: 10.1016/j.engstruct.2005. 09.020].
  • 6Bhaskararao, A.V., Jangid, R.S., 2006c. Harmonic response of adjacent structures connected with a friction damper. Journal of Sound and Vibration, 292(3-5):710-725. [doi: 10.10161j.jsv.2005.08.029d].
  • 7Clough, R., Penzien, J., 2004. Dynamics of Structures (2rd Edition). Computers and Structures, Inc., Berkeley, Cali- fornia, USA.
  • 8Ge, D.D., Zhu, H.P., Wang, D.S., Huang, M.S., 2010. Seismic response analysis of damper-connected adjacent structures with stochastic parameters. Journal of Zhejiang University SCIENCE A (Applied Physics & Engineering), 11(6): 402-414, [doi:10.1631/jzus.A0900345].
  • 9Kasai, K., Maison, B.F., 1997. Building pounding damage during the 1989 Loma Prieta earthquake. Engineering Structures, 19(3):195-207. [doi:10.1016190141-0296(96) 00082-X].
  • 10Kim, J., Ryu, J., Chung, L., 2006. Seismic performance of structures connecting by viscoelastic dampers. Engineer- ing Structures, 28(2):183-195. [doi:10.1016/j.engstruet. 2005.05.014].