摘要 综合运用滤元离线清洗技术(OFECT)、“五要素”铺膜工艺、“八步法”爆膜工艺、“火电厂凝结水精处理混床运行性能诊断及优化专家系统”软件等多项专利或专有技术,对某电厂的凝结水精处理系统进行了运行优化,同时应用了的XTW-C型粉末树脂新产品。优化后,水汽品质明显改善,精处理出水Fe的质量浓度由18~25μg/L降至3μg/L,Cl^-的质量浓度由8~10μg/L降至1μg/L以下,主蒸汽Fe的质量浓度由10~15μg/L降至4μg/L,凝结水Fe的质量浓度由25~30μg/L降至10μg/L,保证了机组的安全运行。 The optimization on operation of condensate polishing system in one power plant was performed by a number of patents or proprietary technologies, such as the OFECT, five-factor precoating techniques, eight-step backwash techniques, software of"Operational Performance Diagnosis and Optimization System for Condensate Polishing Mixed Bed in Thermal Power Plant" etc. Meanwhile, developed XTW-C powdered resin was used. After optimizing, the quality of water-steam cycle was improved obviously. The mass concentration of Fe in effluent of condensate polishing fell to 3 μg/L from 18-25 μg/L and the mass concentration of Cl^- was less than 1μg/L from 8 - 10 μg/L, the mass concentration of Fe fell to 4 μg/L from 10 - 15 μg/L in main steam and to 10 μg/L from 25-30 μg/L in condensate. The results assure the unit safe in operation.
出处 《水处理技术》 CAS CSCD 北大核心 2014年第7期121-123,128,共4页 Technology of Water Treatment
关键词 凝结水精处理 粉末树脂覆盖过滤器 混床 运行优化 XTW粉末树脂 condensate polishing powdex precoat filter mixed bed operating optimization XTW powdered resin
  • 相关文献

参考文献5

  • 1GB/T14427-2008锅炉用水和冷却水分析方法铁的测定[S].
  • 2DL/T954-2005火力发电厂水汽试验方法痕量氟离子、乙酸根离子、甲酸根离子、氯离子、亚硝酸根离子、硝酸根离子、磷酸根离子和硫酸根离子的测定一离子色谱法[S].
  • 3GB/T 12145-2008.火力发电机组及蒸汽动力设备水汽质量[S].
  • 4DL/T912-2005,超临界火力发电机组水汽质量标准[S].
  • 5韩隶传,李志刚,和慧勇.空冷凝汽器的腐蚀和凝结水精处理方式的研讨:2010电厂化学学术会议论文集[C].吉林:中国电机工程学会火电分会,2010:139.

共引文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部