Validating cone-beam computed tomography for peri-implant bone morphometric analysis 被引量:3

Validating cone-beam computed tomography for peri-implant bone morphometric analysis
下载PDF
导出
摘要 Cone-beam computed tomography (CBCT) has been recently used to analyse trabecular bone structure around dental implants. To validate the use of CBCT for three-dimensional (3D) peri-implant trabecular bone morphometry by comparing it to two-dimensional (2D) histology, 36 alveolar bone samples (with implants n=27 vs. without implants n=9) from six mongrel dogs, were scanned ex vivo using a high-resolution (80 ~m) CBCT. After scanning, all samples were decalcified and then sectioned into thin histological sections (-6 jim) to obtain high contrast 2D images. By using CTAn imaging software, bone morphometric parameters including trabecular number (Tb.N), thickness (Tb.Th), separation (Tb.Sp) and bone volume fraction (BV/TV) were examined on both CBCT and corresponding histological images. Higher Tb.Th and Tb.Sp, lower BV/TV and Tb.N were found on CBCT images (P〈0.001). Both measurements on the peri-implant trabecular bone structure showed moderate to high correlation (r=0.65-0.85). The Bland-Altman plots showed strongest agreement for Tb.Th followed by Tb.Sp, Tb.N and BV/TV, regardless of the presence of implants. The current findings support the assumption that peri-implant trabecular bone structures based on high-resolution CBCT measurements are representative for the underlying histological bone characteristics, indicating a potential clinical diagnostic use of CBCT-based peri-implant bone morphometric characterisation. Cone-beam computed tomography (CBCT) has been recently used to analyse trabecular bone structure around dental implants. To validate the use of CBCT for three-dimensional (3D) peri-implant trabecular bone morphometry by comparing it to two-dimensional (2D) histology, 36 alveolar bone samples (with implants n=27 vs. without implants n=9) from six mongrel dogs, were scanned ex vivo using a high-resolution (80 ~m) CBCT. After scanning, all samples were decalcified and then sectioned into thin histological sections (-6 jim) to obtain high contrast 2D images. By using CTAn imaging software, bone morphometric parameters including trabecular number (Tb.N), thickness (Tb.Th), separation (Tb.Sp) and bone volume fraction (BV/TV) were examined on both CBCT and corresponding histological images. Higher Tb.Th and Tb.Sp, lower BV/TV and Tb.N were found on CBCT images (P〈0.001). Both measurements on the peri-implant trabecular bone structure showed moderate to high correlation (r=0.65-0.85). The Bland-Altman plots showed strongest agreement for Tb.Th followed by Tb.Sp, Tb.N and BV/TV, regardless of the presence of implants. The current findings support the assumption that peri-implant trabecular bone structures based on high-resolution CBCT measurements are representative for the underlying histological bone characteristics, indicating a potential clinical diagnostic use of CBCT-based peri-implant bone morphometric characterisation.
出处 《Bone Research》 SCIE CAS 2014年第2期103-109,共7页 骨研究(英文版)
基金 supported by grants from the Interfaculty Council for Development Co-operation (IRO), KU Leuven, Belgium
关键词 BONE CBCT
  • 相关文献

参考文献8

  • 1J Van Dessel,Y Huang,M Depypere,I Rubira-Bullen,F Maes,R Jacobs.A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandible[J].Dentomaxillofacial Radiology.2013(8)
  • 2Eva Klintstr?m,?rjan Smedby,Rodrigo Moreno,Torkel B. Brismar.Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data[J].Skeletal Radiology.2014(2)
  • 3Ruben Pauwels,Jilke Beinsberger,Bruno Collaert,Chrysoula Theodorakou,Jessica Rogers,Anne Walker,Lesley Cockmartin,Hilde Bosmans,Reinhilde Jacobs,Ria Bogaerts,Keith Horner.Effective dose range for dental cone beam computed tomography scanners[J].European Journal of Radiology.2010(2)
  • 4James F. Griffith.Bone mass and architecture determination: state of the art[J].Best Practice & Research Clinical Endocrinology & Metabolism.2008(5)
  • 5W. De Vos,J. Casselman,G.R.J. Swennen.Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: A systematic review of the literature[J].International Journal of Oral & Maxillofacial Surgery.2009(6)
  • 6Sharmila Majumdar.Magnetic resonance imaging for osteoporosis[J].Skeletal Radiology.2008(2)
  • 7P. Mozzo,C. Procacci,A. Tacconi,P. Tinazzi Martini,I. A. Bergamo Andreis.A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results[J].European Radiology.1998(9)
  • 8R Müller,H Van Campenhout,B Van Damme,G Van der Perre,J Dequeker,T Hildebrand,P Rüegsegger.Morphometric Analysis of Human Bone Biopsies: A Quantitative Structural Comparison of Histological Sections and Micro-Computed Tomography[J].Bone.1998(1)

同被引文献11

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部