期刊文献+

Stability of unicortical locked fixation versus bicortical non-locked fixation for forearm fractures

Stability of unicortical locked fixation versus bicortical non-locked fixation for forearm fractures
下载PDF
导出
摘要 Locking plate fixation is being widely applied for fixation of forearm fractures and has many potential advantages, such as fixed angle fixation and improved construct stability, especially in osteoporotic bone. Biomechanical data comparing locking devices to commonly used Low Contact Dynamic Compression (LCDCP) plates for the fixation of forearm fractures has been lacking. The purpose of this study was to compare the fixation stability of a 3.5-mm unicortical locked plate with bicortical non-locked LCDCP plates. Six matched pairs of fresh frozen cadaveric forearms were randomly assigned to unicortical locked and bicortical unlocked groups. Non-destructive four-point bending and torsional test was performed on the ulna and radius separately, using a servohydraulic testing system to obtain construct stiffness of the intact specimens and specimens after osteotomy and plating. The specimens were then loaded to failure to test the fixation strength. The locked unicortical fixation showed significantly higher bending stiffness than the unlocked bicortical fixation, but with significantly lower stiffness and strength in torsion. Fixation strength was comparable between the two groups under bending, but significantly greater in the bicortical non-locked group under torsion. Findings from this study suggest that postoperative rehabilitation protocols may need modification to limit torsional loading in the early stage when using locked unicortical fixation. The study also points out the potential advantage of a hybrid fixation that combines locked unicortical and unlocked bicortical screws. Locking plate fixation is being widely applied for fixation of forearm fractures and has many potential advantages, such as fixed angle fixation and improved construct stability, especially in osteoporotic bone. Biomechanical data comparing locking devices to commonly used Low Contact Dynamic Compression (LCDCP) plates for the fixation of forearm fractures has been lacking. The purpose of this study was to compare the fixation stability of a 3.5-mm unicortical locked plate with bicortical non-locked LCDCP plates. Six matched pairs of fresh frozen cadaveric forearms were randomly assigned to unicortical locked and bicortical unlocked groups. Non-destructive four-point bending and torsional test was performed on the ulna and radius separately, using a servohydraulic testing system to obtain construct stiffness of the intact specimens and specimens after osteotomy and plating. The specimens were then loaded to failure to test the fixation strength. The locked unicortical fixation showed significantly higher bending stiffness than the unlocked bicortical fixation, but with significantly lower stiffness and strength in torsion. Fixation strength was comparable between the two groups under bending, but significantly greater in the bicortical non-locked group under torsion. Findings from this study suggest that postoperative rehabilitation protocols may need modification to limit torsional loading in the early stage when using locked unicortical fixation. The study also points out the potential advantage of a hybrid fixation that combines locked unicortical and unlocked bicortical screws.
出处 《Bone Research》 SCIE CAS 2014年第2期131-135,共5页 骨研究(英文版)
  • 相关文献

参考文献10

  • 1Michael A. Miranda.Locking plate technology and its role in osteoporotic fractures[J].Injury.2007(3)
  • 2Christoph Sommer,Emanuel Gautier,Matthias Müller,David L. Helfet,Michael Wagner.First clinical results of the Locking Compression Plate (LCP)[J].Injury.2003
  • 3Roy Sanders,George J. Haidukewych,Ted Milne,Jay Dennis,Loren L. Latta.Minimal Versus Maximal Plate Fixation Techniques of the Ulna: The Biomechanical Effect of Number of Screws and Plate Length[J].Journal of Orthopaedic Trauma.2002(3)
  • 4C. Krettek,M. Müller,T. Miclau.Evolution of Minimally Invasive Plate Osteosynthesis (MIPO) in the femur[J].Injury.2001
  • 5R. Frigg.Locking Compression Plate (LCP). An osteosynthesis plate based on the Dynamic Compression Plate and the Point Contact Fixator (PC-Fix)[J].Injury.2001
  • 6Andreas Marti,Christoph Fankhauser,André Frenk,Jacques Cordey,Beat Gasser.Biomechanical Evaluation of the Less Invasive Stabilization System for the Internal Fixation of Distal Femur Fractures[J].Journal of Orthopaedic Trauma.2001(7)
  • 7R. Frigg,A. Appenzeller,R. Christensen,A. Frenk,S. Gilbert,R. Schavan.The development of the distal femur Less Invasive Stabilization System (LISS)[J].Injury.2001
  • 8Stephan M. Perren.Minimally invasive internal fixation[J].Injury.2001
  • 9A. W. ElMaraghy,M. W. ElMaraghy,M. Nousiainen,R. R. Richards,E. H. Schemitsch.Influence of the Number of Cortices on the Stiffness of Plate Fixation of Diaphyseal Fractures[J].Journal of Orthopaedic Trauma.2001(3)
  • 10Rina Jain,Nancy Podworny,Thomas M. Hupel,Jordan Weinberg,Emil H. Schemitsch.Influence of Plate Design on Cortical Bone Perfusion and Fracture Healing in Canine Segmental Tibial Fractures[J].Journal of Orthopaedic Trauma.1999(3)