期刊文献+

采用离子色谱法检测电除尘飞灰中的氨含量 被引量:8

Application of Ion-Chromatography Method in Detecting Ammonia Content in Electrostatic Precipitator Fly Ash
下载PDF
导出
摘要 根据离子色谱法检测电除尘飞灰中氨含量的原理,进行检测条件优化试验,得出影响飞灰中氨含量的主要因素有溶液pH值、搅拌时间、水灰比等。在得出最佳试验条件后,进行重复性测试和加标回收率测试,结果表明离子色谱法测定飞灰中氨含量的方法具有较高的精密度和准确度,可作为监测脱硝系统氨逃逸的一种手段。 By applying the principle of ion-chromatography method for testing ammonia content in electrostatic precipitator fly ash, tests to optimize detecting conditions is carried on. It is concluded that the main factors influencing ammonia content in fly ash are pH of solution, mixing time, water and ash ratio and so forth. After optimal test condition is obtained, repeatability test and adding standard recovery rate test are conducted.The results show that ion-chromatography method is of high precision and accuracy in testing ammonia content in electrostatic precipitator fly ash and it can be used to monitor ammonia escape in desulfurization system.
出处 《浙江电力》 2014年第6期43-47,共5页 Zhejiang Electric Power
关键词 离子色谱法 飞灰 氨逃逸量 脱硝系统 ion-chromatography method fly ash ammonia escape amount desulfurization system
  • 相关文献

参考文献10

二级参考文献33

  • 1于龙,张彦军.选择性催化还原(SCR)脱硝技术研究[J].锅炉制造,2005(4):1-4. 被引量:20
  • 2杨忠灿,文军,徐党旗.燃煤锅炉的选择性催化还原烟气脱硝技术[J].广东电力,2006,19(2):13-17. 被引量:33
  • 3温智勇,徐程宏,殷立宝,余岳溪.烟气脱硝工程的调试及其分析[J].广东电力,2007,20(6):51-54. 被引量:7
  • 42007年火电厂脱硫脱硝行业发展报告[J].中国电力环保,2008,(5):1-5.
  • 5杨凯.烟尘烟气连续自动监测系统技术现状和发展趋势(中国环保产业协会环境监测仪器委员会2008年会论文).
  • 6支国庆等.中国电力环保,2008,(2):15-18.
  • 7俞学曾.中国电力环保,2009,(2):6-11.
  • 8HJ/T76-2007固定污染源烟气排放连续监测系统技术要求及监测方法(试行),国家环境保护总局发布.
  • 9Dean W.使用可调谐二极管激光分析仪对氨逃逸量及水汽含量原位测量以优化电厂SCR/SNCR过程与锅炉管监测(第二届中国国际脱硫脱硝技术及设备展览会暨技术研讨会论文).北京,2006.
  • 10绥中发电有限责任公司4号机组烟气脱硝系统性能考核试验报告[R].沈阳:东北电力科学研究院有限公司,2010.