期刊文献+

瞬态热冲击环境下金属蜂窝板结构的热防护特性 被引量:9

Thermal protection performances of metallic honeycomb panel structure at transient thermal shock environment
原文传递
导出
摘要 使用自行研制的高速飞行器瞬态气动热试验模拟系统,对金属蜂窝板结构在多种瞬态热冲击速率下(5℃/s至30℃/s)的隔热特性进行了试验研究,其中最高瞬时温度达到950℃.并采用三维有限元方法对金属蜂窝板结构在高速热冲击环境下的隔热特性进行了数值计算,其计算结果与试验结果吻合性良好,验证了试验方法以及数值模拟方法的可信性和有效性.由试验知金属蜂窝板结构经过950℃热冲击后的翘曲和扭曲变形均很小,特别适合用于制作在高温环境下,要求变形小、质量少的高速飞行器结构部件. By using a self-developed transient aerodynamic thermal simulation system of high-speed aircraft, the heat-shielding performance of metallic honeycomb panel structure was tested at different transient thermal shock rates ranging from 5 ℃/s to 30℃/s, with the maximum instantaneous temperature reaching 950 ℃. Furthermore, a three-dimensional finite element method was established to determine the heat-shielding performance of the metallic honeycomb panel structure at different simulation environments with high thermal shock rates. The numerical calculation results coincide with the corresponding experimental results, verifying the credibility and effectiveness of the experimental methods and the numerical calculation approach. The tested metallic honeycomb panel structure exhibited slight planar flexure and deformation after the experiment in the high-temperature (950 ℃) environment; thus, in the context of high-speed flight vehicles, this structure is particularly suitable for structural components that must be made of lightweight materials with slight deformation in a high-temperature environment.
出处 《航空动力学报》 EI CAS CSCD 北大核心 2014年第6期1261-1271,共11页 Journal of Aerospace Power
基金 国家自然科学基金(11172026) 高等学校博士学科点专项科研基金(20131102110014)
关键词 金属蜂窝板结构 热冲击 高温 热试验 有限元 metallic honeycomb panel structure thermal shock high temperature thermal test finite element
  • 相关文献

参考文献19

  • 1Swann R T, Pittman C M. Analysis of effective thermal eonductivities of honeycomb-core corrugated-core sandwich panels[R]. NASA Technical Note D-714,1961.
  • 2Edwards D K, Arnold J N,Wu P S. Correlations for natural convection through high L/D rectangular cell[J]. Journal of Heat Transfer, 1979,101(12) : 741-743.
  • 3Fusegi T, Hyun J M, Kuwahara K, et al. A numerical study of three dimensional natural convection in a differen- tially heated cubical enclosure[J]. International Journal of Heat and Mass Transfer, 1991,34(6) :1543- 1557.
  • 4Asako Y, Yamaguchi Y, Chen I., et al. Combined natural convection and radiation heat transfer in a vertical air cavi- ty with hexagonal honeycomb core of negligible thickness [J]. Numerical Heat Transfer: Part A,1996,30(1) :73 -85.
  • 5Pepper D W, Hollands K G T. Summary of benchmark nu merical studies 3-D natural convection in an air-filled en- closure[J]. Numerical Heat Transfer: Part A, 2002,42 ( 1/ 2):1-11.
  • 6Wen T,Tian J, Lu T J, et al. Forced convection in metallic honeycomb structures [J]. International Journal of Heat and Mass Transfer,2006,49(19) :3313 -3324.
  • 7LIU Shutian, ZHANG Yongcun, LIU Pang. New analytical model for heat transfer efficiency of metallic honeycomb structures[J]. International Journal of Heat and Mass Transfer,2008,51(25) :6254-6258.
  • 8唐羽烨,薛明德.蜂窝夹芯板的热学与力学特性分析[J].复合材料学报,2005,22(2):130-136. 被引量:31
  • 9景丽,王广飞,唐绍锋,梁军.金属蜂窝夹芯板辐射导热耦合问题[J].哈尔滨工业大学学报,2010,42(5):827-831. 被引量:15
  • 10Johnson D B, Robinson J S. X-43D conceptual design and feasibility study[R]. AIAA 2005-3416,2005.

二级参考文献71