摘要 本文研究粉末衍射仪客观存在的固有角度刻度误差导致的测量角度变化对点阵参数计算精确度的影响,它理论上代表着各台衍射仪(不同实验室)所得到的点阵参数的一致性的极限.具体方法为利用多个带有角度随机误差的多晶硅计算谱,模拟某种制造精度的多台衍射仪的测量结果,并使用三种方法进行点阵参数的拟合计算,从而进行分析. This paper studies the effect of measuring angle error in X-ray powder diffractometer, which is caused by diffractome-ter inherent angle scale error resulting from mechanical manufacture, on the precision of calculated lattice parameter. It represents the theoretical limit of the consistency of the lattice parameters obtained by different diffractometers and laboratories. We use the calculated polysilicon diffraction patterns with random angle error to simulate the results mea-sured by many sets of diffractometers of some manufacturing precision, then calculate and analyze the lattice parameters by three methods.
出处 《物理学报》 SCIE EI CAS CSCD 北大核心 2014年第13期269-274,共6页 Acta Physica Sinica
关键词 X射线衍射仪 固有角度刻度误差 点阵参数 精确度 X-ray diffractometer inherent scale error lattice parameter precision
  • 相关文献

参考文献13

  • 1FEWSTER P F.1999 J. Mater. Sci.-Mater. Electron. 10.175.
  • 2梁敬魁. 粉末衍射法测定晶体结构(下).北京: 科学出版社,p486.
  • 3Chen X C, Zhou J P, Wang H Y, Xu P S, Pan G Q.2011.Chin. Phys. B.20 096102.
  • 4Li G N, Rao G H, Huang Q Z, Gao Q Q, Luo J, Liu G Y, Li J B, Liang J K.2014.Chin. Phys. B 23 036401.
  • 5Wang Z C, He L H, Cuevas F, Latroche M, Shen J, Wang F W.2011.Chin. Phys. B.20 067502.
  • 6Parrish W 1960,Acta Cryst. 13.838.
  • 7Hubbard C R, Swanson H E, Mauer F A 1975 J. Appl. Cryst. 8 45.
  • 8Block S, Hubbard C R 1980 Proceedings of Symposium on Accuracy in Powder Diffraction Maryland June 11-15, 1979.
  • 9陆学善.德拜-谢乐照相中测定流移常数的图解法与点阵间隔的准确测定[J].物理学报,1980,29(3):273-285.
  • 10郭常霖 马利泰.测定非立方晶系晶胞系数的X射线衍射线对法[J].科学通报,1982,27:467-469.

共引文献2

同被引文献23

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部