摘要
应用扫描电镜和能谱分析剖析了上海上电漕泾发电有限公司二级二段反渗透装置的污堵类型,进而介绍了反渗透离线化学清洗的条件、流程、工艺和注意事项。
To analysis fouling type of second grade second stage reverse osmosis device by the scanning electron microscope and energy and energy spectrum analysis ,which for Shanghai Shangdian Caojing Power Generation Corporation. Then to introduce the off-line chemical cleaning condition, cleaning process, process and matters needing attention.
出处
《清洗世界》
CAS
2014年第6期10-14,19,共6页
Cleaning World
关键词
反渗透装置
化学清洗
扫描电镜
能谱分析
reverse osmosis device
chemical cleaning
scanning electron microscope
energy spectrumanalysis