摘要
通过对一段转化炉炉底的温度检测、数据分析和综合热工计算,分析炉底局部超温的原因以及对工艺系统和设备的影响,提出维护建议。
Overheat in regional area of primary reformer bottom and its effect on process system and equipment were studied through temperature detection, data analysis and comprehensive technical thermal calculation. Solutions were also presented.
出处
《大氮肥》
CAS
2014年第3期161-165,共5页
Large Scale Nitrogenous Fertilizer Industry
关键词
一段转化炉
超温
耐火材料
primary reformer
overheat
refractory material