期刊文献+

H_2O_2/Fe^(2+)氧化偶合混凝法处理干膜废水的研究 被引量:2

Study on H_2O_2/Fe^(2+) Oxidative Coupling Followed by Coagulation with Treatment of Dry Film-containing Wastewater
下载PDF
导出
摘要 本文研究了H2 O2 /Fe2 氧化偶合混凝法处理印刷电路板厂干膜废水。讨论了包括过氧化氢浓度、亚铁离子浓度、pH值、温度、时间和混凝 pH值等影响因素。试验结果表明 ,当过氧化氢浓度为 45 7 0mg/L、铁离子浓度为 40 0mg/L、氧化 pH值 4 0、反应温度为 40℃、反应时间 180min时 ,COD去除率达 84 7% 。 The treatment of dry film containing wastewater with oxidation coagulating method was studied Factors affecting Fenton reagent oxidation and coagulation, including the concentration of H 2O 2, the concentration of Fe 2+ , pH, temperature, time and coagulation pH, are discussed The experiment results showed the removal rate of COD reached 87 7%, when the concentration of H 2O 2 was 457 0mg/L, the concentration of Fe 2+ was 400mg/L, pH was 4 0, the time of the reaction was 180min, coagulating pH was 8~9, the quality of effluent could meet the standards
出处 《四川环境》 2001年第1期13-15,20,共4页 Sichuan Environment
关键词 CODCR去除率 过氧化氢 铁离子 干膜废水处理 氧化偶合混凝法 印刷电路板厂 膜分离 Removal rate of COD hydrogen peroxide Fe 2+ wastewater
  • 相关文献

参考文献3

二级参考文献5

  • 1许景文,环境污染与防治,1985年,7卷,5期,1页
  • 2阎岩,化工环保,1992年,12卷,3期,24页
  • 3俞忠原,实验设计与数据分析,1991年
  • 4团体著者,水和废水监测分析方法(第3版),1989年
  • 5许景文,上海环境科学,1987年,6卷,11期,52页

共引文献88

同被引文献37

引证文献2

二级引证文献5