摘要 目的:观察在颅脑磁共振成像 (MRI)检查中 ,口腔内种植体和烤瓷金属冠对MRI影像学诊断的影响。方法 :观察在颅脑MRI检查中 ,CDIC种植体与金属烤瓷修复体的伪影变化。结果 :种植体伪影最小 ,烤瓷钢伪影仅为铸造钢合金的三分之一左右。结论 Objective:To investigate the influence of CDIC dental implant and baked porcelain metal crown on MRI image.Method:The pseudomorphs of two kinds of metal implants were observed during coronal MRI.Results:CDIC dental implantd produces little influence on coronal MRI and the baked porcelain metal crown makes only one thirds of less pseudomorphs than that made by fasting steel.Conclusions:There are no negative effects on diagnosis of coronal MRI with regard to CDIC dental implants and baked porcelain metal crown.
作者 董军 刘宏
出处 《中国口腔种植学杂志》 2001年第1期19-20,33,共3页 Chinese Journal of Oral Implantology
关键词 CDIC种植体 烤瓷金属冠 磁共振成像 伪影 牙种植体 MRI CDIC implant baked porcelain metal crown coronal MRI psudomorph
  • 相关文献

参考文献1

  • 1Stephen T Pomeranz.磁共振诊断粹集[M].河北科学技术出版社,1998.277.

同被引文献33

  • 1赖寿伟,杨华岳.金属固定假牙对头部MR图像的影响研究[J].实用医技杂志,2005,12(02A):350-352. 被引量:11
  • 2刘玉华,孙樱琳.固定义齿修复材料对MRI图像的影响[J].现代口腔医学杂志,2005,19(6):588-589. 被引量:19
  • 3孙樱林,刘玉华.镍铬合金固定修复体对MRI影像的影响[J].现代口腔医学杂志,2007,21(1):72-74. 被引量:17
  • 4Shellock FG, Shellock VJ. Metallic stents: evaluation of MR imaging safety[J].AJR Am J Roentgenol, 1999, 173(3):543-547.
  • 5Hubalkova H, Hora K, Seidl Z, et al. Dental material and magnetic resonance imaging [J]. Eur J Prosthodont Restor Dent, 2002, 10(3) : 125 - 130.
  • 6Thomsen M, Schneider U, Breusch SJ, et al. Artefacts and ferromagnetism dependent on different metal alloys in magnetic resonance imaging. An experimental study[J]. Orthopade, 2001, 30(8) :540- 544.
  • 7Fache JS, Price C, Hawboh EB, et al. MR imaging artifacts produced by dental materials [J]. Am J Neuroradiol, 1987, 8(5):837- 840.
  • 8Eggers G, Rieker M, Kress B, et al. Artefacts in magnetic resonance imaging caused by dental material[ J]. MAGMA,2005, 18(2) : 103 - 111.
  • 9Suh JS, Jeong EK, Shin KH, et al. Minimizing artifacts caused by metallic implants at MR imaging; expeimental and clinical studies[J]. AJR Am J Roentgenol, 1998,171(5) : 1207 - 1213.
  • 10Ganapathi M, Joseph G, Savage R, et al. MRI susceptibility artefacts related to scaphoid screws: the effect of screw type, screw orientation and imaging paranveters[J]. Hand Surg, 2002, 27(2):165- 170.

引证文献3

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部