期刊文献+

胫骨应用解剖与胫骨型髓内分叉钉设计 被引量:4

Applied Anatomy of Tibia and Design of Tibial Intramdulluary Tridentate nail
下载PDF
导出
摘要 目的 :通过胫骨应用解剖测量 ,为胫骨型髓内分叉钉 (TITN )设计提供解剖依据。方法 :采用成人湿胫骨 30及干燥胫骨 2 0根 ,进行胫骨相关解剖测量 ;用 10套 TITN固定胫骨干骨折 ,摄正侧位 X片 ,观察骨折复位及内固定情况。结果 :胫骨下松质区长度 8.12 cm,胫骨下端宽 4.18cm,胫骨下端矢状径 3.6 5 cm,胫骨结节上缘距上关节面距离2 .0 8cm ,胫骨髓腔最狭部矢状径为 1.2 5 cm ,胫骨结节上方骨斜面倾斜角度为 2 1.0°;TITN固定胫骨骨折 ,操作简便 ,骨折解剖复位 ,其远端分叉状结构与胫骨下端漏斗状髓腔良好相容。结论 :TITN设计符合并充分利用胫骨解剖特点 。 Objective:To provide anatomical basis of tibial intramedullary tridentate nail(TITN) by applied anatomy of tibia.Methods:Taking thirty wet and twenty dry adults tibias,the related anatomy measurement of tibiae was made.The fractures of tibiae shafts were fixed by ten TITNs.They were taken radiographs,and reduction and fixation of tibial shafts were studied.Result:The length of low substantia spongiosed region of tidiae was 8.12cm. The width of low part of tibiae was 4.18cm.The length of sagittal axis of low part of tibiae was 3.65cm.The lenth of the top of tibial tuberosity to the surface of the knee joint was 2.08cm.The lest length of sagittal axis of tibial marrow cavities was 1.25cm.The angle of the oblique plane of tibial tuberosity was 21.0°.Fixation of fractures of tibial shafts was simple.Anatomical reduction of fractures was obtained.The tridentate structure of the TITN fit well the funnel-like medullary of the distal part of tibia.Conclusion:TITN was suitable to the special anatomical structure of tibia,and could be used to the fractures of til al shafts.
出处 《实用骨科杂志》 2001年第2期101-104,共4页 Journal of Practical Orthopaedics
关键词 胫骨解剖 胫骨骨折 髓内固定 骨折固定术 Tibia Anatomy Tibial Fracture Medullary fixation
  • 相关文献

参考文献4

二级参考文献5

  • 1王纪湘,中华骨科杂志,1985年,5卷,37页
  • 2王震宇,中华骨科杂志,1994年,14卷,436页
  • 3王之一,中国临床解剖学杂志,1993年,11期,126页
  • 4谭瑞诚,山西医药杂志,1988年,17卷,336页
  • 5关沧江,中华外科杂志,1956年,1期,34页

共引文献72

同被引文献34

  • 1Ritter MA, Davis KE, Meding JB, et al. The effect of alignment and BMI on failure of total knee replacement[J] . J Bone Joint Surg Am, 2011, 93(17): 1588-1596.
  • 2Mahaluxmivala J, Bankes MJ, Nieolai P, et al. The effect of surgeon experience on component positioning in 673 Press Fit Condylar pos- terior cruciate-sacfificing total knee arthroplasties[J]. J Arthroplasty, 2001, 16(5): 635-640.
  • 3Schneider M, Heisel C, Aldinger PR, et al. Use of palpable tendons for extramedullary tibial alignment in total knee arthroplasty[J] . J Arthroplasty, 2007, 22(2): 219-226.
  • 4Sugimura N, Ikeuchi M, Izumi M, et al. The dorsal pedis artery as a new distal landmark for extramedullary tibial alignment in total knee arthroplasty[J] . Knee Surg Sports Traumatol Arthrosc, 2014, 22 (11): 2618-2622.
  • 5Sharkey PF, Hozack WJ, Rothman RH, et al. lnsall Award paper. Why are total knee arthroplasties failing today?[J]. Clin Orthop Relat Res, 2002(404): 7-13.
  • 6Wasielewski RC, Galante JO, Leighty RM, et al. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty[J]. Clin Orthop Relat Res, 1994(299): 31-43.
  • 7Petersen TL, Engh GA. Radiographic assessment of knee alignment after total knee arthroplasty[J]. J Arthroplasty, 1988, 3(1): 67-72.
  • 8Mason JB, Fehring TK, Estok R, et al. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery[J] . J Arthroplasty, 2007, 22 (8) : 1097-1106.
  • 9Meding JB, Berend ME, Ritter MA, et al. Intramedullary vs ex- tramedullary femoral alignment guides: a 15-year follow-up of sur- vivorship[J]. J Arthroplasty, 2011, 26(4): 591-595.
  • 10Dalury DF. Observations of the proximal tibia in total knee arthro- plasty[J]. Clin Orthop Relat Res, 2001(389): 150-155.

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部