新型热力设备停用保护剂性能试验研究 被引量:8

Performance Test and Study of New Type Preservative for the Shut-down Thermal Power Equipment
下载PDF
导出
摘要 论证十八胺在气液两相中的分配系数约为1,指出它分解后的产物不会对水汽品质产生危害。对自行研制的DY-A新型热力设备停用保护剂进行的小型试验和工业试验表明,它能在金属表面形成一层具有良好保护作用的憎水性保护膜,且具有加药剂量低、稳定性好、对水汽品质无影响、投入产出比高等优点。 : It is expounded and proved that octadecylamine distribution coefficient in gaseous phase and liquid phase is about l, and the products of decomposition are not harmful to the quality of water and steam. The performance testings in laboratory and in-situ of new DY-A type preservative made by ourselves show that it can form a layer of hydrophobic film with good protective effect on the metallic surface and has the advantages: lower dosage, good stability, no bad effect on water and steam quality and high cost-effectiveness etc.
出处 《中国电力》 CSCD 北大核心 2001年第4期24-27,共4页 Electric Power
关键词 火力发电厂 热力设备 停用保护剂 性能试验 锅炉 : octadecylamine; film-forming amines; thermal power equipment; preservative shutdown anticorrosion
  • 相关文献

参考文献5

二级参考文献12

  • 1华中电管局赴俄考察组.-[J].华中电力,1993,3(6):98-98.
  • 2李兴.-[J].工业水处理,1992,5(12):20-20.
  • 3李瑛 林海潮 等.第十届全国缓蚀剂学术讨论会论文集[M].,1997,8..
  • 4史美伦,同济大学学报,1995年,23卷,1期,86页
  • 5团体著者,华中电力,1993年,6卷,3期,98页
  • 6团体著者,化学试剂目录手册,1993年
  • 7Zhou Guoding,Bull Electrochem,1992年,7卷,2期,60页
  • 8李兴,工业水处理,1992年,12卷,5期,20页
  • 9张毅然,山西电力技术,1991年,2期
  • 10王杏卿,热力设备腐蚀与防护,1988年