摘要
通过对氨合成塔使用过程中出现的同平面温差现象的分析 ,找出了温差产生的原因 ,提出了修改方法及意见。
The cause formed by temperature difference was found through the analysis of the plane temperature difference phenomena occurred in the operation process in the ammonia converter and the modification method and comments are presented.
出处
《化肥设计》
CAS
2001年第1期48-49,53,共3页
Chemical Fertilizer Design
关键词
氨合成塔
偏心
偏流
同平面温差
ammonia converter, temperature difference, deflecti