期刊文献+

KY140—728反应性计 被引量:1

KY140-728 Reactivity Meter (Simulating Reactivity)
下载PDF
导出
摘要 本文推导了KY140—728反应性计所使用的基本公式。在此公式的基础上确定了总体方框图。文中较详细的介绍了KY142—728六组缓发中子电路插件,导出模拟积分器参数与堆参数的联系。介绍了两个插件及整机性能在实验室测试情况。最后介绍在堆上标定及实用考验结果。 This paper deduced the basic formula which is used for Model KY140-728 Reactivity Meter.The.block-diagram of the reactivity meter based on the formula has been given. Medel KY142-728 plug-in unit with six groups of delayed neutron circuit has been introduced in detail, the relationship between simulative integrator parameter and reactor parameter has been given in this paper. The testing results of two plug-in units (Model KY142-728, KY143-728) and whole instrument in the laboratory were discribed.The results of calibration in the reactor are given.
作者 关新铎
机构地区 北京核仪器厂
出处 《核电子学与探测技术》 CAS CSCD 北大核心 1991年第6期349-354,共6页 Nuclear Electronics & Detection Technology
关键词 反应性计 反应堆 反应性 周期 当量 Reactivity, Rod equivalent, Period
  • 相关文献

同被引文献6

  • 1Auerbach J M,Carpenter S G. A Microprocessor Con- trolled Reactivity Meter For Real Time Monitoring Of Reactors[ J]. IEEE Transactions on Nuclear Science, 1978,25 ( 1 ) :98 - 100.
  • 2Ansari S A. Development of On - Line Reactivity Me- ter for Nuclear Reactors [ J ]. IEEE Transactions On Nuclear Science, 1991,38 (4) : 946 - 952.
  • 3Suzuki E,Tsunoda T. A Reactivity Meter and Its Ap- plication [ J ]. Journal of Nuclear Science and Tech- nology,1964, 1(6):210-218.
  • 4Bacastow J L, Swiekard E O. Test of Six High Tem- perature Neutron Detectors to 650?℃ [ J ]. IEEE Transactions on Nuclear Science, 1969,16 ( 1 ) : 177 - 183.
  • 5Jammes C, Filliatre P, Geslot B, et al. Assessment of the High Temperature Fission Chamber Technology for the French Fast Reactor Program [ J ]. IEEE Transac- tions on Nuclear Science, 2012,59 (4) : 1351 - 1359.
  • 6黄礼渊.反应堆物理试验用便携式数字反应性仪实堆考验试验[J].核电子学与探测技术,2010,30(4):472-475. 被引量:2