四种局麻方式对Phaco患者眼压变化的观察 被引量:6

Effects of four kinds of local anesthesia on intraocular pressure in eyes undergoing Phaco
原文传递
导出
摘要 为对比评价四种方式局麻与眼压变化的关系。方法 :连续性选取 6 0例老年性白内障 PEA+ IOL住院手术患者 ,随机分至球后、球周、角膜缘球结膜下及表面麻醉组。分别于麻醉前、麻醉后、麻醉后 5分钟及 10分钟用非接触式眼压计测量眼压。结果 :球后及球周组在麻醉后眼压较麻醉前均升高 ,结膜下组与表麻组未见显著差异。各种麻醉技术之间对比结果显示 ,球后组与球周组对麻醉前后眼压影响在麻醉后及 5 min后差异有显著性 ,球后组眼压增高较小 ,降低较快 ;10 min后差异不显著。球后组较结膜下和表麻组眼压在麻醉后升高 ,10 min后降低 ,球周组较结膜下组及表麻组在麻醉后及 5 min时均高 ,10 min时差异不显著。结膜下组与表麻组始终无显著差异。结论 :球后及球周麻醉较结膜下及表面麻醉前后的眼压变化大 ,且个体眼压反应有很大差异 。 To investigate the effect on intraocular pressure(IOP)of four finds of local anesthesia in eyes undergoing Phaco.Methods:A total of 60 eyes were studied.They were randomized to four groups:retrobulbar anesthesia,peribulbar anesthesia,subconjunstival anesthesia and topical anesthesia group.Intraocular pressure was measured before,immediately after,and 5 and 10 minutes after anesthesia by non contact tonometer.Result:The mean IOP after anesthesia rose significantly in group I and 2,but not in group 3 and 4.By comparison,the mean rose of group 1 was smaller than group 2 immediately after and 5 minutes after anethesia,but the same 10 minutes after.The mean IOP increase of group 1 immediately after,and 5 minutes after anesthesia,and the decrease 10 minutes after were statisically significant different with group 3 and 4.The mean IOP in crease of group 2 immediately after,and 5 minutes after anesthesia were significant different with group 3 and 4,but had no significant difference 10 minutes after.There were not significant difference between group 3 and 4.Conclusions:The mean IOP change in retrobulbar aneshesia and peribulbar anesthesia with ocular compreeession was much more than in subconjunstival anesthesia and topical anesthesia,and had individual difference.
出处 《中国实用眼科杂志》 CSCD 北大核心 2001年第3期192-194,共3页 Chinese Journal of Practical Ophthalmology
关键词 局部麻醉 眼压 白内障摘除术 PHACO Anesthesia Intraocular pressure Cataract extraction
  • 相关文献

参考文献2

  • 1李凤鸣.眼科全书,第六卷[M].北京人民卫生出版社,1996.1729.
  • 2李凤鸣,眼科全书.6,1996年,1729页

同被引文献34

  • 1Hayren SS. Anterior ischemic optic neuropathy. IV. Occurrence after cataract extraction[ J]. Arch Ophthalmol. 1980,98 : 1410-1414.
  • 2Wedrich A, Menapace R, Stifter S. The influence of the incision length on the early postoperative intraocutar pressure following cataract surgery [ J ]. Int Ophthalmn1,2004,18 (2) :77-80.
  • 3Biro Z, Balogh T, Change in intraocular pressure within 1 week of phacoemulsification and intraocular lens implantation using Adatocol [ J ]. J Cataract Refract Surg. 2006,32 (4) :573-576.
  • 4Lagreze WD, Bomer TG, Funk J, Effect of surgical technique on the increase in introcular presure after cataract extraction [ J ]. Ophthalmic Surg Lasers, 1996,27 ( 3 ) :169-173.
  • 5Kanski J J.临床眼科学(徐国兴译)[M].福州:福建科学技术出版社,2006:207-211.
  • 6葛坚.眼科学[M].2版.北京:人民卫生出版社,2010:496-500.
  • 7Gomez-Amau JI,Yanguela J,GonzalezA,et al.Anaesthesia-related diplopia after cataract surgery.Br J Anaesth,003,90:189-193.
  • 8Kaderli B,Avci R.Small-incision manual extracapsular cataract extraction using deep-topical,nerve-block anesthesia.Ophthalmic Surg Lasers Imaging,004,35:460-464.
  • 9陈瑞英.眼科手术学.见:杨钧主编.现代眼科手册.北京:人民卫生出版社,1993.666-668
  • 10林志彬,金有豫.医用药理学基础[M].第5版.北京:世界图书出版公司.2002:29

引证文献6

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部