摘要
为对比评价四种方式局麻与眼压变化的关系。方法 :连续性选取 6 0例老年性白内障 PEA+ IOL住院手术患者 ,随机分至球后、球周、角膜缘球结膜下及表面麻醉组。分别于麻醉前、麻醉后、麻醉后 5分钟及 10分钟用非接触式眼压计测量眼压。结果 :球后及球周组在麻醉后眼压较麻醉前均升高 ,结膜下组与表麻组未见显著差异。各种麻醉技术之间对比结果显示 ,球后组与球周组对麻醉前后眼压影响在麻醉后及 5 min后差异有显著性 ,球后组眼压增高较小 ,降低较快 ;10 min后差异不显著。球后组较结膜下和表麻组眼压在麻醉后升高 ,10 min后降低 ,球周组较结膜下组及表麻组在麻醉后及 5 min时均高 ,10 min时差异不显著。结膜下组与表麻组始终无显著差异。结论 :球后及球周麻醉较结膜下及表面麻醉前后的眼压变化大 ,且个体眼压反应有很大差异 。
To investigate the effect on intraocular pressure(IOP)of four finds of local anesthesia in eyes undergoing Phaco.Methods:A total of 60 eyes were studied.They were randomized to four groups:retrobulbar anesthesia,peribulbar anesthesia,subconjunstival anesthesia and topical anesthesia group.Intraocular pressure was measured before,immediately after,and 5 and 10 minutes after anesthesia by non contact tonometer.Result:The mean IOP after anesthesia rose significantly in group I and 2,but not in group 3 and 4.By comparison,the mean rose of group 1 was smaller than group 2 immediately after and 5 minutes after anethesia,but the same 10 minutes after.The mean IOP increase of group 1 immediately after,and 5 minutes after anesthesia,and the decrease 10 minutes after were statisically significant different with group 3 and 4.The mean IOP in crease of group 2 immediately after,and 5 minutes after anesthesia were significant different with group 3 and 4,but had no significant difference 10 minutes after.There were not significant difference between group 3 and 4.Conclusions:The mean IOP change in retrobulbar aneshesia and peribulbar anesthesia with ocular compreeession was much more than in subconjunstival anesthesia and topical anesthesia,and had individual difference.
出处
《中国实用眼科杂志》
CSCD
北大核心
2001年第3期192-194,共3页
Chinese Journal of Practical Ophthalmology