期刊文献+

大功率移相调宽DC/DC变换器

High Power Shift - Phase PWM DC/DC Converter
下载PDF
导出
摘要 文中简要介绍了移相调宽软开关变换器的基本工作原理,详细叙述了具有逐脉限流功能的控制电路,并给出了功率高达14.4kW的设计实例,实验结果表明这种变换器的整机效率高达90%。在移相调宽软开关变换器中由于开关器件工作在零压开通和准零压关断模式,从而消除了硬开关变换器的固有缺陷。 In this paper, the principle of shift - phase PWM soft - switching converter is introduced in brief. Because the device is turned on zero - voltage and turned off pseudo - zero - voltage, the defect of hard - switching is eliminated. The control scheme in which the current is limited pulse by pulse is narrated in detail, the design example of power up to 14.4kW is gaven,and testing result shows the total efficiency of the converter reaches up to 90% .
机构地区 华中科技大学
出处 《通信电源技术》 2001年第1期14-16,共3页 Telecom Power Technology
关键词 DC/DC变换器 移相调宽 软开关 逐脉限流 converter,shift - phase PWM , soft - switching,current limited pulse by pulse
  • 相关文献

参考文献3

  • 1[1]Richard Redl, Nathan O. Sokal and Laszlo Balogh. A Novel Soft-Switching Full-Bridge DC/DC Converter:Analysis,Design Considerations,and Experimental Results at 1.5kW, 100kHz. IEEE Transactions on Power Electronics,1991.408~418
  • 2[2]Jung- Goo Cho, Juan A. Saba', Guichao Hua, and Fred C. Lee. Zero - Voltage and Zero-Current-Switching Full Bridge PWM Converter for High- Power Applications. IEEE Transactions on Power Electronis, 1996.622627
  • 3杨德刚,赵良炳.软开关技术回顾与展望[J].电力电子技术,1998,32(2):96-101. 被引量:24