通过对传统热流计缺点的分析,研究了新型热管式热流计的结构尺寸和设计准则,并通过现场测试证实了此种热流计的应用可行性。
Through the research of the shortcomings of the traditional heat flux metre,the structure dimension and design criteria of the new kind of heat pipe heat flux meter was given.In addition,its application feasibility was testified through the spot test.