摘要
分析了安全阀运行中产生震颤和泄漏的原因 ,给出了安全阀接管座结构改进方法。通过改善安全阀的工作状况 。
Due to unreasonable structure design and installation arrangement,causing the safety valve trembling and leaking easily during operation.The safety valve working condition is improved effectually and the stable/operation of unit guaranteed throw the improvement of safety valve's connection hole.The improvement method is introduced in this article.
出处
《阀门》
2001年第2期38-39,共2页
VALVE MAGAZINE