摘要 介绍了一种精密光点测试系统。它采用脉冲方法刷新光点 ,并且刷新频率和电源频率保持同步 ,从而避免了扫描及视频方法引起的测量误差 ,同时避免了散逸电磁场的影响 ;并克服了采用扫描光栅、通过信号发生器或者测试软件产生测试信号来进行测试的系统存在的问题。该测试系统尤其适合电子枪和偏转线圈设计人员进行精密的光点测试分析。 A novel technique has been successfully developed to precisely measure the spot size in a monitor.In this technique,the spot size is updated by an electric pulse which synchronizes the frequencies of the scanning signal and the main power so that influence of the electric and/or magnetic stray field can be considerably reduced.The technical advantages over the conventional spot size measurements as well as its applications in the design of electron guns and deflection coils were also discussed.
出处 《真空科学与技术》 CSCD 北大核心 2001年第2期140-142,共3页 Vacuum Science and Technology
  • 相关文献

参考文献2

  • 1Keller P A.Electronic Display Measurement.John Wiley & Sons,INC,1997
  • 2Bukal B,Nemeth K C.New Electron-beam Profile and Convergence Measurement Method.Digest SID′99,1999:886~889

同被引文献8

  • 1李晓华,真空科学与技术学报,2001年,2期
  • 2Li Xiaowei,内部报告.Dong Fei Display Tube Design Research Center SEU,2000年
  • 3胡广书,数字信号处理.理论、算法与实现,1997年
  • 4Yang Xiaowei.Measurement technique & measurement equipment. Philips Report(TVR-650-00-GvV/DO49),July 2000,22~32.
  • 5Naoki Shiramatsu. Improvement in measuring the luminance distribution of the CRT electron beam spot.SID,2000,624~627.
  • 6Nijs C.van der Vaart. A novel electron source for CRTs. Information Display(SID),2002,18(6):14~17.
  • 7陈福朝,杨晓伟,郑姚生,李晓华.光点测试仪阴极脉冲电路设计[J].电子器件,2000,23(4):281-285. 被引量:3
  • 8杨晓伟,陈福朝,李晓华.光点测试仪阴极脉冲放大器的改进设计[J].电子技术应用,2001,27(11):32-35. 被引量:1

引证文献4

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部