期刊文献+

电晕线串并联的脉冲电晕放电特性 被引量:8

Pulse Corona Discharge Characteristics of the Line-to-plate Reactor with Series and Parallel Corona Wire
下载PDF
导出
摘要 在线板结构脉冲电晕放电试验模型上 ,测试了不同长度电晕线串并联时的 ns脉冲电晕放电伏安特性 ,研究了电晕线串并联时脉冲电晕放电的不同特点。研究表明 ns脉冲电晕放电伏安特性呈指数函数上升趋势 ,串联电晕线的电晕电流随其长度的增长为自然对数函数上升趋势 ,并联电晕线的电晕电流随其长度的增长为线形函数上升趋势。根据研究 ,实际设计脉冲电晕放电反应器时 ,为提高反应器效率 ,多根电晕线应并联而不宜串联 。 The V A characteristics of nanosecond pulse corona discharge with different corona wire length in series and parallel in the line to plate pulse corona discharge reactor is measured.It investigates the different features of the pulse corona discharge while the corona wires are connected in series and parallel. It is known from the study that the V A characteristics of nanosecond pulse corona discharge trends to rise as exponential function. The corona currents with the wire in series increase as logarithmic function with the increase of the corona wire. But the corona currents with the wire in parallel increase as linear function with the increase of the corona wire. The results suggest that the corona wires is better to be connected in parallel in practical design for getting high corona discharge efficiency and the corona wire shouldn’t be long.
作者 何正浩 李劲
机构地区 华中科技大学
出处 《高电压技术》 EI CAS CSCD 北大核心 2001年第1期47-49,共3页 High Voltage Engineering
关键词 线板反应器 纳秒脉冲 电晕放电 串并联 line to plate reactor nanosecond pulse corona discharge corona wire series and parallel