摘要
列出美国及国内某厂起动型铅蓄电池失效故障的原因统计 ,对PE隔板发生的慢性短路现象 ,试用形成的枝晶数来求证 。
WT5”BZ]Based on the statistic data of the mode of failures of lead acid batteries by BCI and a factory in China,the causes of chronic internal short circuit of PE separators by a bypothesis of dendrites formation were found.Also some measures to prevent internal short circuit from dendrites formation were suggested.
出处
《电池》
CAS
CSCD
北大核心
2001年第2期88-89,共2页
Battery Bimonthly