摘要
本文介绍了QFSN2—200—2型汽轮发电机负序能力试验的情况及测量结果,讨论了转子表面的损耗及涡流,确定了该电机稳态及瞬态的不平衡电流值。
In this paper,the test condition and measurement results negative sequence capability of QFSN_2—200—2 type turbogenerator are introduced and the distributed of loss and eddy current on the rotor surface are discussed too, meanwhile the steady and transient value of the unbalanced current of the turbogenerator are determined.
出处
《大电机技术》
北大核心
1989年第1期17-24,共8页
Large Electric Machine and Hydraulic Turbine