简述了用约瑟夫森阵列电压标准校准 Fluke752A分压箱的方法。对于 10:1和100:1量程,其比例测量的不确定度分别为1×10-7和3×10-7。
In this paper, the method to calibrate Fluke 752A divider by using Josephson voltage standard is introduced. The measurement uncertainties of divider ratio are 1 x 10-7 for 10:l range and 3 x 10-7 for 100:l range.