期刊文献+

毛细管区带电泳法测定复方磺胺甲噁唑片中两组分的含量 被引量:5

Determination of two constituents in compound sulfamethoxazole tablets by capillary zone electrophoresis
下载PDF
导出
摘要 建立毛细管区带电泳法测定复方磺胺甲口恶唑片中磺胺甲口恶唑和甲氧苄啶含量的方法。用 2 5mmol/L硼砂缓冲液分离 ,以氯霉素为内标 ,2 14nm为测定波长。结果 :样品中二组分完全分离且呈良好线性关系 ,加样回收率分别为 10 1.0 % ( RSD =1.4 3% ) ,10 0 .3% ( RSD =1.2 8% )。 To establish a capillary zone electrophoresis method for the assay of compound sulfamethoxazole tablets. The buffer used was borax solution(25mmol/L). The internal standard was chloramphenicol and the detective wavelength was 214nm. Sulfamethoxazole and trimethoprim were separated completely. The average recoveries were 101 0%(RSD=1 43%) and 100 3%(RSD=1 28%) respectively.
出处 《西北药学杂志》 CAS 2001年第2期51-52,共2页 Northwest Pharmaceutical Journal
关键词 毛细管区带电泳法 复方磺胺甲恶唑片 磺胺甲恶唑 甲氧苄淀 含量测定 capillary zone electrophoresis(CZE), compound sulfamethoxazole tablets, sulfamethoxazole, trimethoprim
  • 相关文献

参考文献4

共引文献8

同被引文献64

  • 1董丹,邵兵,吴永宁,吴国华,薛颖,徐淑坤,涂晓明,张彦锋.液相色谱-电喷雾串联四极杆质谱法测定鸡肉中17种磺胺类药物的残留[J].色谱,2005,23(4):404-407. 被引量:46
  • 2谢玉璇,谢天尧,刘秋英,官春华.毛细管电泳-电导法分离检测磺胺嘧啶、磺胺甲嘧啶和磺胺二甲嘧啶[J].分析测试学报,2006,25(3):100-102. 被引量:20
  • 3Pleasance S,Blay P,Quilllam M A.Determination of sulfonamides by liquid chroma tography ultraviolet diode array detection and ion-spray tandem mass spectrometry with application to cultured salmon flesh.J of Chromatogr,1991,558(1):155-173.
  • 4吕保英.食品分析大全(第1卷)[J].高等教育出版社,1997,:895-941.
  • 5LITTLETIELD N. Chronic toxicity and carcinogenecity studies of sulfamethazine in B6CFI mice[R]. National Center for Toxicological Research Jefferson. AR. 1988.
  • 6ZHANG J Y, HU Z D, CHEN X G. Quantification of glutathione and glutathione disulfide in human plasma and tobacco leaves by capillary electrophoresis with laser-induced fluorescence detection [J]. Talanta, 2005, 65 (4): 986 -990.
  • 7BURGI D S, CHIEN R L. Optimization in sample stacking for high-performance capillan, electrophoresis[J]. Anal Chem, 1991, 63(18) : 2042 -2047.
  • 8SZOKO E, TABI T, HALASZ A S, et al. High sensitivity analysis of nitrite and nitrate in biological samples by capillary zone eleetrophoresis with transient isotachophoretic sample stacking[J]. J Chromatogr: A, 2004, 1051 ( 1 -2) : 177 - 183.
  • 9QUIRINO J P, TERABE S, BOCEK P. Sweeping of neutral analytes in electrokinetic chromatography with high-salt-containing matrixes[J]. Anal Chem, 2000, 72(8) : 1934 -1940.
  • 10SU A K, CHANG Y S, LIN C H. Analysis of riboflavin in beer by capillary eleetrophoresis/blue light emitting diode (LED) -induced fluoresceuce detection combined with a dynamic pH junction technique [J]. Talanta, 64 (4), 2004 : 970 - 974.

引证文献5

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部