针对石油化工总厂循环冷却水系统多元醇磷酸酯复合配方处理效果不太理想的现实 ,选用了新型全有机碱性复合配方 ,经现场应用表明 :缓蚀率为 0 .11mm/a ,但杀菌效果欠佳。
As the treating results of multi-alcohol phosphate composite formula were not so good in the cooling water system of a petrochemical complex, the new type organic alkaline composite formula was selected for the process. The field application showed that the corrosion inhibition rate was 0.91 mm/yr but the bacteria killing ability was not satisfactory.