摘要
通过对某沿海电厂除盐系统不能正常运行的分析,提出了在除盐装置之前串接反渗透装置的设想,并经过技术经济比较,确定部分原水通过RO处理后进入除盐系统的技改方案,使除盐系统能够满足原水水质大幅度变化的要求.
Through the analysis of the case that the demineralization system of a coastal power plant can't be operated in normal condition, an assumption is presented that a reverse osmosis installation in a serial arrangement should be designed upstream. After technical and economic analysis of the scheme, a technical renovation proposal is presented that partial raw water should flow into the demineralization system after the RO treatment so that the system can follow the great variation of raw water quality.
出处
《上海电力学院学报》
CAS
2001年第1期35-38,共4页
Journal of Shanghai University of Electric Power
关键词
水处理
反渗透系统
除盐系统
锅炉
电厂
water quality
reverse osmosis
ion exchange
demineralization