摘要
提出了一种简单、实用的测定色釉料颗粒分布的方法 ,该方法的原理基于斯托克斯定律。本研究以锆镨黄色料颗粒分析的实例为代表将该方法的测定结果与采用激光颗粒分析仪的测定结果进行了比较 ,并重点讨论了分散剂含量、分散手段和操作方法等因素对结果准确性的影响。
A simple,effective method to measure the particle diameter and particle distribution of pigment is introduced in this article.This is based on law stokes.As far as zirconium-praseodymium yellow is concerned,the result of this method is compared with that of malvern instrument Ltd,and this article does discuss the effect of disperser,disperse method and operation ect on the accuracy of measurement.
出处
《中国陶瓷工业》
CAS
北大核心
2001年第1期1-4,共4页
China Ceramic Industry
关键词
陶瓷
色料颗粒分布
沉降法
色釉料
分散
系统误差
particle distribution,sedimentation process,pigment and glass dispersion,system difference