摘要
通过对某高层住宅PVC U排水管道安装质量存在的问题进行现场调查 ,利用排列图找到了影响安装质量的主要因素 ,然后采用因果分析图法分析了导致这些质量问题产生的原因 ,并提出了相应的对策和措施。
A field quality investigation to examine the installation of PVC U drainage pipeline in a high rise building was conducted jointly by the designers and constructors. The main factors affecting installation quality were found by a permutation diagram and the reasons that caused these failures were analyzed by causality analysis methods. Finally an appropriate way and some consolidated measures were given to deal with these problems.
出处
《给水排水》
CSCD
北大核心
2001年第5期78-80,共3页
Water & Wastewater Engineering