摘要 通过对昌黎台测区环境变化的调查和电测剖面、井液电阻率等测量结果 ,分析了该台近十年来电阻率变化发展的过程及其变化原因。结果表明测区附近热矿水的扩散、废污水的渗流和降雨等诸多因素的影响是昌黎台地电阻率多年趋势下降变化的主要原因。 Based on the investigation to the environment of the Changli Seismostation,its electromotive profile and its resistivity of well water,The reasons and the process of the earth resistivity's variation in the station are analyzed.The results show that the main reasons of the earth resistivity's reduction is the combining effect of the diffusion of hot mineral water,the vadose of waste water around the station and rain.
出处 《华北地震科学》 2001年第2期62-67,共6页 North China Earthquake Sciences
关键词 昌黎地电台 地电阻率 电测剖面 废污水 热矿水 降雨 Changli Station earth resistivity eletromotive profile