期刊文献+

410t/h锅炉燃烧调整试验研究 被引量:1

Studies of Combustion Adjustments of a 410t/h Boiler
下载PDF
导出
摘要 该文分析了娘子关电厂 3号炉大修后运行过程中发生炉内结渣和灭火的原因 ,介绍了通过燃烧调整解决炉内结渣和低负荷不投油稳燃的经验 ,对同类型锅炉的燃烧调整有借鉴作用。图 The paper analyzes reasons why slugging and flame failures occurred during operation after an overhaul and describes experiences gained with combustion adjustments, that solved the slagging problem, and those in stabilizing low load, without resorting to combustion at fuel oil. The paper may serve as a reference for combustion adjustment work of boiler, of similar types. Fig 1, tables 7 and refs 4
出处 《发电设备》 2001年第3期1-3,14,共4页 Power Equipment
关键词 锅炉 燃烧调整 试验 电厂 boiler slagging combustion adjustment